TY - JOUR
T1 - 2.9 Å Resolution Cryo-EM 3D Reconstruction of Close-Packed Virus Particles
AU - Liu, Zheng
AU - Guo, Fei
AU - Wang, Feng
AU - Li, Tian Cheng
AU - Jiang, Wen
N1 - Publisher Copyright:
© 2016 Elsevier Ltd All rights reserved.
PY - 2016/2/2
Y1 - 2016/2/2
N2 - Single-particle cryoelectron microscopy typically discards close-packed particle images as unusable data. Here, we report an image processing strategy and case study of obtaining near-atomic resolution 3D reconstructions from close-packed particles. Multiple independent de novo initial models were constructed to determine and cross-validate the particle parameters. The particles with consistent views were further refined including not only Euler angles and center positions but also defocus, astigmatism, beam tilt, and overall and anisotropic magnification. We demonstrated this strategy with a 2.9 Å resolution reconstruction of a 1.67 MDa virus-like particle of a circovirus, PCV2, recorded on 86 photographic films. The map resolution was further validated with a phase-randomization test and local resolution assessment, and the atomic model was validated with MolProbity and EMRinger. Close-packed virus particles were thus shown not only to be useful for high-resolution 3D reconstructions but also to allow data collection at significantly improved throughput for near-atomic resolution reconstructions.
AB - Single-particle cryoelectron microscopy typically discards close-packed particle images as unusable data. Here, we report an image processing strategy and case study of obtaining near-atomic resolution 3D reconstructions from close-packed particles. Multiple independent de novo initial models were constructed to determine and cross-validate the particle parameters. The particles with consistent views were further refined including not only Euler angles and center positions but also defocus, astigmatism, beam tilt, and overall and anisotropic magnification. We demonstrated this strategy with a 2.9 Å resolution reconstruction of a 1.67 MDa virus-like particle of a circovirus, PCV2, recorded on 86 photographic films. The map resolution was further validated with a phase-randomization test and local resolution assessment, and the atomic model was validated with MolProbity and EMRinger. Close-packed virus particles were thus shown not only to be useful for high-resolution 3D reconstructions but also to allow data collection at significantly improved throughput for near-atomic resolution reconstructions.
UR - http://www.scopus.com/inward/record.url?scp=84954290403&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=84954290403&partnerID=8YFLogxK
U2 - 10.1016/j.str.2015.12.006
DO - 10.1016/j.str.2015.12.006
M3 - Article
C2 - 26777413
AN - SCOPUS:84954290403
SN - 0969-2126
VL - 24
SP - 319
EP - 328
JO - Structure
JF - Structure
IS - 2
ER -