T1 - A completely implanted left ventricular assist device. Chronic in vivo testing
AU - Weiss, William
AU - Rosenberg, Gerson
AU - Snyder, A. J.
AU - Donachy, J.
AU - Reibson, J.
AU - Kawaguchi, O.
AU - Sapirstein, J. S.
AU - Pae, Walter
AU - Pierce, W. S.
PY - 1993
Y1 - 1993
N2 - A completely implantable left ventricular assist device (LVAD) designed for permanent circulatory support has recently been tested in animals without the use of percutaneous leads, using transcutaneous energy transmission and wireless telemetry. The LVAD consists of a brushless DC motor and rollerscrew energy converter, a pusher plate actuated blood pump with a seamless segmented polyurethane blood sac, Bjork-Shiley Delrin disk monostrut valves, an implanted compliance chamber, an implanted electronic controller and battery, and a transcutaneous energy transmission system. The blood pump/energy converter assembly weighs 565 g and displaces 295 cc. The dynamic stroke volume is 60 ml, and the maximum output is 9 L/min. Pump output is automatically controlled to maintain full stroke volume as preload varies. Hall effect sensors for detecting rotary position of the motor are the only sensors used. Six bovine implants were performed, with durations of 84, 208, 244, 130, 70 (ongoing), and 15 (ongoing) days. Four animals used two-way telemetry, whereas the remaining two used one-way (outgoing) telemetry. These first chronic in vivo tests with the Penn State completely implanted LVAD system have demonstrated that it is a feasible solution to long-term ventricular support.
AB - A completely implantable left ventricular assist device (LVAD) designed for permanent circulatory support has recently been tested in animals without the use of percutaneous leads, using transcutaneous energy transmission and wireless telemetry. The LVAD consists of a brushless DC motor and rollerscrew energy converter, a pusher plate actuated blood pump with a seamless segmented polyurethane blood sac, Bjork-Shiley Delrin disk monostrut valves, an implanted compliance chamber, an implanted electronic controller and battery, and a transcutaneous energy transmission system. The blood pump/energy converter assembly weighs 565 g and displaces 295 cc. The dynamic stroke volume is 60 ml, and the maximum output is 9 L/min. Pump output is automatically controlled to maintain full stroke volume as preload varies. Hall effect sensors for detecting rotary position of the motor are the only sensors used. Six bovine implants were performed, with durations of 84, 208, 244, 130, 70 (ongoing), and 15 (ongoing) days. Four animals used two-way telemetry, whereas the remaining two used one-way (outgoing) telemetry. These first chronic in vivo tests with the Penn State completely implanted LVAD system have demonstrated that it is a feasible solution to long-term ventricular support.
UR - http://www.scopus.com/inward/record.url?scp=0027376629&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=0027376629&partnerID=8YFLogxK
U2 - 10.1097/00002480-199307000-00055
DO - 10.1097/00002480-199307000-00055
M3 - Article
C2 - 8268572
AN - SCOPUS:0027376629
SN - 1058-2916
VL - 39
SP - M427-M432
JO - ASAIO Journal
JF - ASAIO Journal
IS - 3
ER -