TY - JOUR
T1 - A portable air cleaner partially reduces the upper respiratory response to sidestream tobacco smoke
AU - Bascom, Rebecca
AU - Fitzgerald, Thomas K.
AU - Kesavanathan, Jana
AU - Swift, David L.
N1 - Copyright:
Copyright 2017 Elsevier B.V., All rights reserved.
PY - 1996/6
Y1 - 1996/6
N2 - Environmental tobacco smoke (ETS) is a common indoor pollutant which often causes acute upper respiratory tract symptoms and measurable nasal congestion. This study evaluated the effect of a room air cleaner on the response to sidestream tobacco smoke (SS) in 12 healthy, nonsmoking adults with previously documented subjective and objective upper respiratory congestive responses to SS. Each subject served as his or her own control and was exposed in a climate- controlled chamber on 2 days, each separated by at least 2 weeks, to SS (15 ppm carbon monoxide, 2 hours, at rest) in the presence of a functioning (AC) or sham room air cleaner. Subjects recorded symptoms and underwent posterior rhinomanometry and acoustic rhinometry. The AC significandy reduced the concentration of particles, total organic vapors, and nicotine, but not carbon monoxide. The AC reduced symptoms of headache [1.4 ± 0.3 sham (net postexposure) versus 0.5 ± 0.2 AC, p < 0.001, analysis of variance] and rhinorrhea (1.8 ± 0.4 sham versus 0.8 ± 0.3 AC, p < 0.0001) and minimum cross-sectional area of the nasal passage (-0.11 ± 0.06 cm2 sham versus –0.02 ± 0.03 cm2 AC, p < 0.0.01). Symptoms of nasal congestion, nasal irritation, and measured mid-nasal volume were not altered. These data indicate that a portable room air cleaner can significandy reduce, although not eliminate, the acute response to a relatively high concentration of SS in healthy subjects with a history of symptoms associated with ETS exposure.
AB - Environmental tobacco smoke (ETS) is a common indoor pollutant which often causes acute upper respiratory tract symptoms and measurable nasal congestion. This study evaluated the effect of a room air cleaner on the response to sidestream tobacco smoke (SS) in 12 healthy, nonsmoking adults with previously documented subjective and objective upper respiratory congestive responses to SS. Each subject served as his or her own control and was exposed in a climate- controlled chamber on 2 days, each separated by at least 2 weeks, to SS (15 ppm carbon monoxide, 2 hours, at rest) in the presence of a functioning (AC) or sham room air cleaner. Subjects recorded symptoms and underwent posterior rhinomanometry and acoustic rhinometry. The AC significandy reduced the concentration of particles, total organic vapors, and nicotine, but not carbon monoxide. The AC reduced symptoms of headache [1.4 ± 0.3 sham (net postexposure) versus 0.5 ± 0.2 AC, p < 0.001, analysis of variance] and rhinorrhea (1.8 ± 0.4 sham versus 0.8 ± 0.3 AC, p < 0.0001) and minimum cross-sectional area of the nasal passage (-0.11 ± 0.06 cm2 sham versus –0.02 ± 0.03 cm2 AC, p < 0.0.01). Symptoms of nasal congestion, nasal irritation, and measured mid-nasal volume were not altered. These data indicate that a portable room air cleaner can significandy reduce, although not eliminate, the acute response to a relatively high concentration of SS in healthy subjects with a history of symptoms associated with ETS exposure.
UR - http://www.scopus.com/inward/record.url?scp=0029933041&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=0029933041&partnerID=8YFLogxK
U2 - 10.1080/1047322X.1996.10389373
DO - 10.1080/1047322X.1996.10389373
M3 - Article
AN - SCOPUS:0029933041
SN - 1047-322X
VL - 11
SP - 553
EP - 559
JO - Applied Occupational and Environmental Hygiene
JF - Applied Occupational and Environmental Hygiene
IS - 6
ER -