T1 - A simple model for falling film absorption on vertical tubes in the presence of non-absorbables
AU - Medrano, Marc
AU - Bourouis, Mahmoud
AU - Perez-Blanco, Horacio
AU - Coronas, Alberto
N1 - Funding Information:
M. Medrano would like to thank CIRIT for a fellowship. This work was co-financed by the Spanish Science and Technology Ministry within the Programme “PROFIT”.
PY - 2003/1
Y1 - 2003/1
N2 - Most water-lithium bromide (LiBr) absorption chillers have a purge system to remove non-absorbable gases that cause a reduction in cooling capacity. Generally, the non-absorbables are originated in corrosion/passivation processes inside the machine, but leaks can also be a source of concern. However, since leaks must be corrected immediately to avoid machine deterioration, this study is mostly aimed at the non-absorbables evolved during operation. This paper analyses the effect of inlet non-absorbable air concentration, outlet purge velocity, absorber pressure and cooling water temperature on the falling film absorption process inside a vertical tube absorber, based on a simple transport coefficient model. This model consists of three ordinary differential equations solved with as method for initial-value problem, and a set of auxiliary equations. The study shows that the effect of non-absorbables can be significant, and furthermore provides a quantitative framework to aid in purge design. The nominal working conditions in this study were a solution Reynolds number of 100, an absorber pressure of 1.3 kPa, a cooling water temperature of 35 °C and an inlet solution concentration of 62% LiBr by weight. The results indicate that a minimum vapour velocity is required to sweep the non-absorbables along the absorber towards the purge, thus preventing reduced absorption fluxes. At a cooling water temperature of 35 °C, an inlet air concentration of 20% (by mole) resulted in a 61% reduction in mass absorption flux.
AB - Most water-lithium bromide (LiBr) absorption chillers have a purge system to remove non-absorbable gases that cause a reduction in cooling capacity. Generally, the non-absorbables are originated in corrosion/passivation processes inside the machine, but leaks can also be a source of concern. However, since leaks must be corrected immediately to avoid machine deterioration, this study is mostly aimed at the non-absorbables evolved during operation. This paper analyses the effect of inlet non-absorbable air concentration, outlet purge velocity, absorber pressure and cooling water temperature on the falling film absorption process inside a vertical tube absorber, based on a simple transport coefficient model. This model consists of three ordinary differential equations solved with as method for initial-value problem, and a set of auxiliary equations. The study shows that the effect of non-absorbables can be significant, and furthermore provides a quantitative framework to aid in purge design. The nominal working conditions in this study were a solution Reynolds number of 100, an absorber pressure of 1.3 kPa, a cooling water temperature of 35 °C and an inlet solution concentration of 62% LiBr by weight. The results indicate that a minimum vapour velocity is required to sweep the non-absorbables along the absorber towards the purge, thus preventing reduced absorption fluxes. At a cooling water temperature of 35 °C, an inlet air concentration of 20% (by mole) resulted in a 61% reduction in mass absorption flux.
UR - http://www.scopus.com/inward/record.url?scp=0037211753&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=0037211753&partnerID=8YFLogxK
U2 - 10.1016/S0140-7007(02)00015-4
DO - 10.1016/S0140-7007(02)00015-4
M3 - Article
AN - SCOPUS:0037211753
SN - 0140-7007
VL - 26
SP - 108
EP - 116
JO - International Journal of Refrigeration
JF - International Journal of Refrigeration
IS - 1
ER -