T1 - A systematic review of follow-up results of additively manufactured customized implants for the pelvic area
AU - Zoltan, Jeffrey
AU - Popescu, Diana
AU - Sanei, Seyed Hamid Reza
N1 - Publisher Copyright:
© 2023 Informa UK Limited, trading as Taylor & Francis Group.
PY - 2023
Y1 - 2023
N2 - Introduction: While 3D printing of bone models for preoperative planning or customized surgical templating has been successfully implemented, the use of patient-specific additively manufactured (AM) implants is a newer application not yet well established. To fully evaluate the advantages and shortcomings of such implants, their follow-up results need to be evaluated. Area Covered: This systematic review provides a survey of the reported follow-ups on AM implants used for oncologic reconstruction, total hip arthroplasty both primary and revision, acetabular fracture, and sacrum defects. Expert Opinion: The review shows that Titanium alloy (Ti4AL6V) is the most common type of material system used due to its excellent biomechanical properties. Electron beam melting (EBM) is the predominant AM process for manufacturing implants. In almost all cases, porosity at the contact surface is implemented through the design of lattice or porous structures to enhance osseointegration. The follow-up evaluations show promising results, with only a small number of patients suffering from aseptic loosening, wear, or malalignment. The longest reported follow-up length was 120 months for acetabular cages and 96 months for acetabular cups. The AM implants have proven to serve as an excellent option to restore premorbid skeletal anatomy of the pelvis.
AB - Introduction: While 3D printing of bone models for preoperative planning or customized surgical templating has been successfully implemented, the use of patient-specific additively manufactured (AM) implants is a newer application not yet well established. To fully evaluate the advantages and shortcomings of such implants, their follow-up results need to be evaluated. Area Covered: This systematic review provides a survey of the reported follow-ups on AM implants used for oncologic reconstruction, total hip arthroplasty both primary and revision, acetabular fracture, and sacrum defects. Expert Opinion: The review shows that Titanium alloy (Ti4AL6V) is the most common type of material system used due to its excellent biomechanical properties. Electron beam melting (EBM) is the predominant AM process for manufacturing implants. In almost all cases, porosity at the contact surface is implemented through the design of lattice or porous structures to enhance osseointegration. The follow-up evaluations show promising results, with only a small number of patients suffering from aseptic loosening, wear, or malalignment. The longest reported follow-up length was 120 months for acetabular cages and 96 months for acetabular cups. The AM implants have proven to serve as an excellent option to restore premorbid skeletal anatomy of the pelvis.
UR - http://www.scopus.com/inward/record.url?scp=85150298623&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85150298623&partnerID=8YFLogxK
U2 - 10.1080/17434440.2023.2183839
DO - 10.1080/17434440.2023.2183839
M3 - Review article
C2 - 36860182
AN - SCOPUS:85150298623
SN - 1743-4440
VL - 20
SP - 233
EP - 244
JO - Expert Review of Medical Devices
JF - Expert Review of Medical Devices
IS - 3
ER -