TY - JOUR
T1 - Accelerometer test-retest reliability by data processing algorithms
T2 - Results from the Twin cities walking study
AU - Sirard, John R.
AU - Forsyth, Ann
AU - Oakes, J. Michael
AU - Schmitz, Kathryn H.
PY - 2011/7
Y1 - 2011/7
N2 - Background: The purpose of this study was to determine 1) the test-retest reliability of adult accelerometermeasured physical activity, and 2) how data processing decisions affect physical activity levels and test-retest reliability. Methods: 143 people wore the ActiGraph accelerometer for 2 7-day periods, 1 to 4 weeks apart. Five algorithms, varying nonwear criteria (20 vs. 60 min of 0 counts) and minimum wear requirements (6 vs. 10 hrs/day for ≥ 4 days) and a separate algorithm requiring ≥ 3 counts per min and ≥ 2 hours per day, were used to process the accelerometer data. Results: Processing the accelerometer data with different algorithms resulted in different levels of counts per day, sedentary, and moderate-to-vigorous physical activity. Reliability correlations were very good to excellent (ICC = 0.70-0.90) for almost all algorithms and there were no significant differences between physical activity measures at Time 1 and Time 2. Conclusions: This paper presents the first assessment of test-retest reliability of the Actigraph over separate administrations in free-living subjects. The ActiGraph was highly reliable in measuring activity over a 7-day period in natural settings but data were sensitive to the algorithms used to process them.
AB - Background: The purpose of this study was to determine 1) the test-retest reliability of adult accelerometermeasured physical activity, and 2) how data processing decisions affect physical activity levels and test-retest reliability. Methods: 143 people wore the ActiGraph accelerometer for 2 7-day periods, 1 to 4 weeks apart. Five algorithms, varying nonwear criteria (20 vs. 60 min of 0 counts) and minimum wear requirements (6 vs. 10 hrs/day for ≥ 4 days) and a separate algorithm requiring ≥ 3 counts per min and ≥ 2 hours per day, were used to process the accelerometer data. Results: Processing the accelerometer data with different algorithms resulted in different levels of counts per day, sedentary, and moderate-to-vigorous physical activity. Reliability correlations were very good to excellent (ICC = 0.70-0.90) for almost all algorithms and there were no significant differences between physical activity measures at Time 1 and Time 2. Conclusions: This paper presents the first assessment of test-retest reliability of the Actigraph over separate administrations in free-living subjects. The ActiGraph was highly reliable in measuring activity over a 7-day period in natural settings but data were sensitive to the algorithms used to process them.
UR - http://www.scopus.com/inward/record.url?scp=79959538162&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=79959538162&partnerID=8YFLogxK
U2 - 10.1123/jpah.8.5.668
DO - 10.1123/jpah.8.5.668
M3 - Article
C2 - 21734312
AN - SCOPUS:79959538162
SN - 1543-3080
VL - 8
SP - 668
EP - 674
JO - Journal of Physical Activity and Health
JF - Journal of Physical Activity and Health
IS - 5
ER -