Accelerometer use in a physical activity intervention trial

Melissa A. Napolitano, Kelley E. Borradaile, Beth A. Lewis, Jessica A. Whiteley, Jaime L. Longval, Alfred F. Parisi, Anna E. Albrecht, Christopher N. Sciamanna, John M. Jakicic, George D. Papandonatos, Bess H. Marcus

Research output: Contribution to journalArticlepeer-review

35 Scopus citations

Abstract

This paper describes the application of best practice recommendations for using accelerometers in a physical activity (PA) intervention trial, and the concordance of different methods for measuring PA. A subsample (n=63; 26%) of the 239 healthy, sedentary adults participating in a PA trial (mean age=47.5; 82% women) wore the ActiGraph monitor at all 3 assessment time points. ActiGraph data were compared with self-report (i.e., PA weekly recall and monthly log) and fitness variables. Correlations between the PA recall and ActiGraph for moderate intensity activity ranged from 0.16-0.48 and from 0.28-0.42 for vigorous intensity activity. ActiGraph and fitness [estimated VO2(ml/kg/min)] had correlations of 0.15-0.45. The ActiGraph and weekly self-report were significantly correlated at all time points (correlations ranged from 0.23 to 0.44). In terms of detecting intervention effects, intervention groups recorded more minutes of at least moderate-intensity PA on the ActiGraph than the control group at 6months (min=46.47, 95% CI=14.36-78.58), but not at 12months. Limitations of the study include a small sample size and only 3days of ActiGraph monitoring. To obtain optimal results with accelerometers in clinical trials, the authors recommend following best practice recommendations: detailed protocols for monitor use, calibration of monitors and validation of data quality, and use of validated equations for analysis. The ActiGraph has modest concordance with other assessment tools and is sensitive to change over time. However, until more information validating the use of accelerometry in clinical trials becomes available, properly administered self-report measures of PA should remain part of the assessment battery.

Original languageEnglish (US)
Pages (from-to)514-523
Number of pages10
JournalContemporary Clinical Trials
Volume31
Issue number6
DOIs
StatePublished - Nov 2010

All Science Journal Classification (ASJC) codes

  • Pharmacology (medical)

Fingerprint

Dive into the research topics of 'Accelerometer use in a physical activity intervention trial'. Together they form a unique fingerprint.

Cite this