Actual knee motion during continuous passive motion protocols is less than expected

Jesse E. Bible, Andrew K. Simpson, Debdut Biswas, Richard R. Pelker, Jonathan N. Grauer

Research output: Contribution to journalArticlepeer-review

25 Scopus citations

Abstract

Investigations of the usefulness of continuous passive motion (CPM) after TKA have yielded mixed results, with evidence suggesting its efficacy is contingent on the presence of larger motion arcs. Surprisingly, the range of motion (ROM) the knee actually experiences while in a CPM machine has not been elucidated. In this study, the ability of a CPM apparatus to bring about a desired knee ROM was assessed with an electrogoniometer. The knee experienced only 68% to 76% of the programmed CPM arc, with the higher percentages generated by elevating the head of the patient's bed. This disparity between true knee motion and CPM should be accounted for when designing CPM protocols for patients or investigations evaluating efficacy of CPM.

Original languageEnglish (US)
Pages (from-to)2656-2661
Number of pages6
JournalClinical orthopaedics and related research
Volume467
Issue number10
DOIs
StatePublished - Oct 2009

All Science Journal Classification (ASJC) codes

  • Surgery
  • Orthopedics and Sports Medicine

Fingerprint

Dive into the research topics of 'Actual knee motion during continuous passive motion protocols is less than expected'. Together they form a unique fingerprint.

Cite this