TY - JOUR
T1 - Assessing function and endurance in adults with spinal and bulbar muscular atrophy
T2 - validity of the adult myopathy assessment tool
AU - Harris-Love, Michael O
AU - Fernandez-Rhodes, Lindsay
AU - Joe, Galen
AU - Shrader, Joseph A
AU - Kokkinis, Angela
AU - La Pean Kirschner, Alison
AU - Auh, Sungyoung
AU - Chen, Cheunju
AU - Li, Li
AU - Levy, Ellen
AU - Davenport, Todd E
AU - Di Prospero, Nicholas A
AU - Fischbeck, Kenneth H
PY - 2014
Y1 - 2014
N2 - Purpose. The adult myopathy assessment tool (AMAT) is a performance-based battery comprised of functional and endurance subscales that can be completed in approximately 30 minutes without the use of specialized equipment. The purpose of this study was to determine the construct validity and internal consistency of the AMAT with a sample of adults with spinal and bulbar muscular atrophy (SBMA). Methods. AMAT validity was assessed in 56-male participants with genetically confirmed SBMA (mean age, 53 ± 10 years). The participants completed the AMAT and assessments for disease status, strength, and functional status. Results. Lower AMAT scores were associated with longer disease duration (r = -0.29; P < 0.03) and lower serum androgen levels (r = 0.49-0.59; P < 0.001). The AMAT was significantly correlated with strength and functional status (r = 0.82-0.88; P < 0.001). The domains of the AMAT exhibited good internal consistency (Cronbach's α = 0.77-0.89; P < 0.001). Conclusions. The AMAT is a standardized, performance-based tool that may be used to assess functional limitations and muscle endurance. The AMAT has good internal consistency, and the construct validity of the AMAT is supported by its significant associations with hormonal, strength, and functional characteristics of adults with SBMA. This trial is registered with Clinicaltrials.gov identifier NCT00303446.
AB - Purpose. The adult myopathy assessment tool (AMAT) is a performance-based battery comprised of functional and endurance subscales that can be completed in approximately 30 minutes without the use of specialized equipment. The purpose of this study was to determine the construct validity and internal consistency of the AMAT with a sample of adults with spinal and bulbar muscular atrophy (SBMA). Methods. AMAT validity was assessed in 56-male participants with genetically confirmed SBMA (mean age, 53 ± 10 years). The participants completed the AMAT and assessments for disease status, strength, and functional status. Results. Lower AMAT scores were associated with longer disease duration (r = -0.29; P < 0.03) and lower serum androgen levels (r = 0.49-0.59; P < 0.001). The AMAT was significantly correlated with strength and functional status (r = 0.82-0.88; P < 0.001). The domains of the AMAT exhibited good internal consistency (Cronbach's α = 0.77-0.89; P < 0.001). Conclusions. The AMAT is a standardized, performance-based tool that may be used to assess functional limitations and muscle endurance. The AMAT has good internal consistency, and the construct validity of the AMAT is supported by its significant associations with hormonal, strength, and functional characteristics of adults with SBMA. This trial is registered with Clinicaltrials.gov identifier NCT00303446.
U2 - 10.1155/2014/873872
DO - 10.1155/2014/873872
M3 - Article
C2 - 24876969
SN - 2090-2867
VL - 2014
SP - 873872
JO - Rehabilitation Research and Practice
JF - Rehabilitation Research and Practice
ER -