Automated aortic calcification detection in low-dose chest CT images

Yiting Xie, Yu Maw Htwe, Jennifer Padgett, Claudia Henschke, David Yankelevitz, Anthony P. Reeves

Research output: Chapter in Book/Report/Conference proceedingConference contribution

8 Scopus citations

Abstract

The extent of aortic calcification has been shown to be a risk indicator for vascular events including cardiac events. We have developed a fully automated computer algorithm to segment and measure aortic calcification in low-dose noncontrast, non-ECG gated, chest CT scans. The algorithm first segments the aorta using a pre-computed Anatomy Label Map (ALM). Then based on the segmented aorta, aortic calcification is detected and measured in terms of the Agatston score, mass score, and volume score. The automated scores are compared with reference scores obtained from manual markings. For aorta segmentation, the aorta is modeled as a series of discrete overlapping cylinders and the aortic centerline is determined using a cylinder-tracking algorithm. Then the aortic surface location is detected using the centerline and a triangular mesh model. The segmented aorta is used as a mask for the detection of aortic calcification. For calcification detection, the image is first filtered, then an elevated threshold of 160 Hounsfield units (HU) is used within the aorta mask region to reduce the effect of noise in low-dose scans, and finally non-aortic calcification voxels (bony structures, calcification in other organs) are eliminated. The remaining candidates are considered as true aortic calcification. The computer algorithm was evaluated on 45 low-dose non-contrast CT scans. Using linear regression, the automated Agatston score is 98.42% correlated with the reference Agatston score. The automated mass and volume score is respectively 98.46% and 98.28% correlated with the reference mass and volume score.

Original languageEnglish (US)
Title of host publicationMedical Imaging 2014
Subtitle of host publicationComputer-Aided Diagnosis
PublisherSPIE
ISBN (Print)9780819498281
DOIs
StatePublished - 2014
EventMedical Imaging 2014: Computer-Aided Diagnosis - San Diego, CA, United States
Duration: Feb 18 2014Feb 20 2014

Publication series

NameProgress in Biomedical Optics and Imaging - Proceedings of SPIE
Volume9035
ISSN (Print)1605-7422

Other

OtherMedical Imaging 2014: Computer-Aided Diagnosis
Country/TerritoryUnited States
CitySan Diego, CA
Period2/18/142/20/14

All Science Journal Classification (ASJC) codes

  • Electronic, Optical and Magnetic Materials
  • Atomic and Molecular Physics, and Optics
  • Biomaterials
  • Radiology Nuclear Medicine and imaging

Fingerprint

Dive into the research topics of 'Automated aortic calcification detection in low-dose chest CT images'. Together they form a unique fingerprint.

Cite this