Automatic estimation of heart boundaries and cardiothoracic ratio from chest x-ray images

  • Ahmed H. Dallal
  • , Chirag Agarwal
  • , Mohammad R. Arbabshirani
  • , Aalpen Patel
  • , Gregory Moore

Research output: Chapter in Book/Report/Conference proceeding › Conference contribution

Abstract

Cardiothoracic ratio (CTR) is a widely used radiographic index to assess heart size on chest X-rays (CXRs). Recent studies have suggested that also two-dimensional CTR might contain clinical information about the heart function. However, manual measurement of such indices is both subjective and time consuming. This study proposes a fast algorithm to automatically estimate CTR indices based on CXRs. The algorithm has three main steps: 1) model based lung segmentation, 2) estimation of heart boundaries from lung contours, and 3) computation of cardiothoracic indices from the estimated boundaries. We extended a previously employed lung detection algorithm to automatically estimate heart boundaries without using ground truth heart markings. We used two datasets: a publicly available dataset with 247 images as well as clinical dataset with 167 studies from Geisinger Health System. The models of lung fields are learned from both datasets. The lung regions in a given test image are estimated by registering the learned models to patient CXRs. Then, heart region is estimated by applying Harris operator on segmented lung fields to detect the corner points corresponding to the heart boundaries. The algorithm calculates three indices, CTR1D, CTR2D, and cardiothoracic area ratio (CTAR). The method was tested on 103 clinical CXRs and average error rates of 7.9%, 25.5%, and 26.4% (for CTR1D, CTR2D, and CTAR respectively) were achieved. The proposed method outperforms previous CTR estimation methods without using any heart templates. This method can have important clinical implications as it can provide fast and accurate estimate of cardiothoracic indices.

Original languageEnglish (US)
Title of host publicationMedical Imaging 2017
Subtitle of host publicationComputer-Aided Diagnosis
EditorsNicholas A. Petrick, Samuel G. Armato
PublisherSPIE
ISBN (Electronic)9781510607132
DOIs
StatePublished - 2017
EventMedical Imaging 2017: Computer-Aided Diagnosis - Orlando, United States
Duration: Feb 13 2017 → Feb 16 2017

Publication series

NameProgress in Biomedical Optics and Imaging - Proceedings of SPIE
Volume10134
ISSN (Print)1605-7422

Conference

ConferenceMedical Imaging 2017: Computer-Aided Diagnosis
Country/TerritoryUnited States
CityOrlando
Period2/13/17 → 2/16/17