TY - JOUR
T1 - Biomechanical Comparison of Fibertape Device Repair Techniques of Ligamentous Lisfranc Injury in a Cadaveric Model
AU - Koroneos, Zachary
AU - Vannatta, Emily
AU - Kim, Morgan
AU - Cowman, Trevin
AU - Fritsche, Madelaine
AU - Kunselman, Allen R.
AU - Lewis, Gregory S.
AU - Aynardi, Michael
N1 - Publisher Copyright:
© 2021
PY - 2021/4
Y1 - 2021/4
N2 - Background: Lisfranc ligamentous injuries are complex, and their treatment, along with the preferred method of fixation, is controversial. Implementing a flexible synthetic augmentation device (fibertape) has been described as an alternative to traditional screw fixation. This biomechanical study evaluated two fibertape devices with interference screw fixation: InternalBrace, and InternalBrace with supplementary intercuneiform stabilization. Methods: The diastasis and relative angular displacement between bones were measured at three midfoot joints in the Lisfranc articulation. Measurements were obtained for the pre-injured, injured, and post-fixation stages under static loading. Specimens then underwent stepwise increases in cyclic loading performed at 1 Hz and 100 cycles, at 100 N ground reaction force intervals from 500 to 1200 N to simulate postoperative loading, and then up to 1800 N to simulate high loads. Failure of fixation was defined as diastasis greater than 2 millimeters at the second-metatarsal – medial-cuneiform joint. Results: InternalBrace specimens demonstrated failures in 3 of 9 (33%) specimens at cyclic loads of 1000 N. Conversely, InternalBrace with Supplementary Limb specimens had 1 failure at 1200 N. The difference in diastasis at the second metatarsal-medial cuneiform joint was statistically significant between the two groups at higher loads of 1600N (p = 0.019) and 1800N (p = 0.029). Conclusion: The use of InternalBrace for ligamentous Lisfranc injuries appears to provide a biomechanically viable alternative for withstanding early postoperative protected weight bearing. Furthermore, the use of a supplementary limb in addition to the InternalBrace fibertape fixation method appears to enhance its biomechanical efficacy.
AB - Background: Lisfranc ligamentous injuries are complex, and their treatment, along with the preferred method of fixation, is controversial. Implementing a flexible synthetic augmentation device (fibertape) has been described as an alternative to traditional screw fixation. This biomechanical study evaluated two fibertape devices with interference screw fixation: InternalBrace, and InternalBrace with supplementary intercuneiform stabilization. Methods: The diastasis and relative angular displacement between bones were measured at three midfoot joints in the Lisfranc articulation. Measurements were obtained for the pre-injured, injured, and post-fixation stages under static loading. Specimens then underwent stepwise increases in cyclic loading performed at 1 Hz and 100 cycles, at 100 N ground reaction force intervals from 500 to 1200 N to simulate postoperative loading, and then up to 1800 N to simulate high loads. Failure of fixation was defined as diastasis greater than 2 millimeters at the second-metatarsal – medial-cuneiform joint. Results: InternalBrace specimens demonstrated failures in 3 of 9 (33%) specimens at cyclic loads of 1000 N. Conversely, InternalBrace with Supplementary Limb specimens had 1 failure at 1200 N. The difference in diastasis at the second metatarsal-medial cuneiform joint was statistically significant between the two groups at higher loads of 1600N (p = 0.019) and 1800N (p = 0.029). Conclusion: The use of InternalBrace for ligamentous Lisfranc injuries appears to provide a biomechanically viable alternative for withstanding early postoperative protected weight bearing. Furthermore, the use of a supplementary limb in addition to the InternalBrace fibertape fixation method appears to enhance its biomechanical efficacy.
UR - http://www.scopus.com/inward/record.url?scp=85102899893&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85102899893&partnerID=8YFLogxK
U2 - 10.1016/j.injury.2021.02.077
DO - 10.1016/j.injury.2021.02.077
M3 - Article
C2 - 33745699
AN - SCOPUS:85102899893
SN - 0020-1383
VL - 52
SP - 692
EP - 698
JO - Injury
JF - Injury
IS - 4
ER -