TY - JOUR
T1 - Carbon-ring microelectrode arrays for electrochemical imaging of single cell exocytosis
T2 - Fabrication and characterization
AU - Lin, Yuqing
AU - Trouillon, Raphaël
AU - Svensson, Maria I.
AU - Keighron, Jacqueline D.
AU - Cans, Ann Sofie
AU - Ewing, Andrew G.
PY - 2012/3/20
Y1 - 2012/3/20
N2 - Fabrication of carbon microelectrode arrays, with up to 15 electrodes in total tips as small as 10-50 μm, is presented. The support structures of microelectrodes were obtained by pulling multiple quartz capillaries together to form hollow capillary arrays before carbon deposition. Carbon ring microelectrodes were deposited by pyrolysis of acetylene in the lumen of these quartz capillary arrays. Each carbon deposited array tip was filled with epoxy, followed by beveling of the tip of the array to form a deposited carbon-ring microelectrode array (CRMA). Both the number of the microelectrodes in the array and the tip size are independently tunable. These CRMAs have been characterized using scanning electron microscopy, energy dispersive X-ray spectroscopy, and electrogenerated chemiluminescence. Additionally, the electrochemical properties were investigated with steady-state voltammetry. In order to demonstrate the utility of these fabricated microelectrodes in neurochemistry, CRMAs containing eight microring electrodes were used for electrochemical monitoring of exocytotic events from single PC12 cells. Subcellular temporal heterogeneities in exocytosis (i.e. cold spots vs hot spots) were successfully detected with the CRMAs.
AB - Fabrication of carbon microelectrode arrays, with up to 15 electrodes in total tips as small as 10-50 μm, is presented. The support structures of microelectrodes were obtained by pulling multiple quartz capillaries together to form hollow capillary arrays before carbon deposition. Carbon ring microelectrodes were deposited by pyrolysis of acetylene in the lumen of these quartz capillary arrays. Each carbon deposited array tip was filled with epoxy, followed by beveling of the tip of the array to form a deposited carbon-ring microelectrode array (CRMA). Both the number of the microelectrodes in the array and the tip size are independently tunable. These CRMAs have been characterized using scanning electron microscopy, energy dispersive X-ray spectroscopy, and electrogenerated chemiluminescence. Additionally, the electrochemical properties were investigated with steady-state voltammetry. In order to demonstrate the utility of these fabricated microelectrodes in neurochemistry, CRMAs containing eight microring electrodes were used for electrochemical monitoring of exocytotic events from single PC12 cells. Subcellular temporal heterogeneities in exocytosis (i.e. cold spots vs hot spots) were successfully detected with the CRMAs.
UR - http://www.scopus.com/inward/record.url?scp=84863374207&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=84863374207&partnerID=8YFLogxK
U2 - 10.1021/ac3000368
DO - 10.1021/ac3000368
M3 - Article
C2 - 22339586
AN - SCOPUS:84863374207
SN - 0003-2700
VL - 84
SP - 2949
EP - 2954
JO - Analytical Chemistry
JF - Analytical Chemistry
IS - 6
ER -