TY - JOUR
T1 - Cardiac function in congenital adrenal hyperplasia
T2 - A pattern of reversible cardiomyopathy
AU - Minette, Mary S.
AU - Hoyer, Andrew W.
AU - Pham, Phat P.
AU - Deboer, Mark D.
AU - Reller, Mark D.
AU - Boston, Bruce A.
PY - 2013/6
Y1 - 2013/6
N2 - Objective To evaluate cardiac function in infants with congenital adrenal hyperplasia (CAH) before and after corticosteroid replacement therapy. Study design This prospective, case-control study included 9 infants with CAH. Cardiac function was assessed by echocardiography at presentation and after corticosteroid replacement therapy. Six term infants underwent 2 echocardiograms each and served as the control group. Data on fractional shortening (FS), rate-corrected velocity of circumferential fiber shortening (Vcf), wall stress, tissue Doppler indices, myocardial performance index, left ventricular mass, and Vcf/wall stress were obtained. Results The infants with CAH exhibited myocardial dysfunction at baseline and lower systolic blood pressure (SBP) compared with the control group. FS, a measure of systolic contractility, differed significantly from before to after corticosteroid treatment (mean, 32.3% ± 4.7% pretreatment, 39.9% ± 5.0% posttreatment). Vcf, a preload- independent measure of cardiac contractility, also differed significantly before and after treatment (mean, 1.23 ± 0.16 circumferences/second pretreatment, 1.45 ± 0.22 circumferences/second posttreatment). SBP was also lower (mean, 84 ± 9.3 mmHg) and improved with treatment (mean, 95 ± 4.8 mmHg). The control group demonstrated no statistically significant changes in FS, Vcf, or SBP. There was a change in left ventricular mass in the control group between the 2 studies. Conclusion Newborns with CAH have evidence for cardiac dysfunction at baseline that reverses with corticosteroid replacement therapy. These data suggest that corticosteroids play a direct role in modulating cardiac function in the newborn.
AB - Objective To evaluate cardiac function in infants with congenital adrenal hyperplasia (CAH) before and after corticosteroid replacement therapy. Study design This prospective, case-control study included 9 infants with CAH. Cardiac function was assessed by echocardiography at presentation and after corticosteroid replacement therapy. Six term infants underwent 2 echocardiograms each and served as the control group. Data on fractional shortening (FS), rate-corrected velocity of circumferential fiber shortening (Vcf), wall stress, tissue Doppler indices, myocardial performance index, left ventricular mass, and Vcf/wall stress were obtained. Results The infants with CAH exhibited myocardial dysfunction at baseline and lower systolic blood pressure (SBP) compared with the control group. FS, a measure of systolic contractility, differed significantly from before to after corticosteroid treatment (mean, 32.3% ± 4.7% pretreatment, 39.9% ± 5.0% posttreatment). Vcf, a preload- independent measure of cardiac contractility, also differed significantly before and after treatment (mean, 1.23 ± 0.16 circumferences/second pretreatment, 1.45 ± 0.22 circumferences/second posttreatment). SBP was also lower (mean, 84 ± 9.3 mmHg) and improved with treatment (mean, 95 ± 4.8 mmHg). The control group demonstrated no statistically significant changes in FS, Vcf, or SBP. There was a change in left ventricular mass in the control group between the 2 studies. Conclusion Newborns with CAH have evidence for cardiac dysfunction at baseline that reverses with corticosteroid replacement therapy. These data suggest that corticosteroids play a direct role in modulating cardiac function in the newborn.
UR - http://www.scopus.com/inward/record.url?scp=84880570717&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=84880570717&partnerID=8YFLogxK
U2 - 10.1016/j.jpeds.2012.11.086
DO - 10.1016/j.jpeds.2012.11.086
M3 - Article
C2 - 23337094
AN - SCOPUS:84880570717
SN - 0022-3476
VL - 162
SP - 1193-1198.e1
JO - Journal of Pediatrics
JF - Journal of Pediatrics
IS - 6
ER -