N2 - Aims Very elderly patients have not been well-represented in the randomized trials that established the benefits of cardiac resynchronization therapy (CRT) in heart failure (HF) patients. We therefore compared clinical outcomes in CRT-defibrillator (CRT-D) recipients ≥80 and <80 years old. Methods and results We compared mortality and time to first appropriate shock in 258 consecutive CRT-D patients ≥80 years old with New York Heart Association II-IV HF, left ventricular ejection fraction ≤35%, QRS duration ≥120 ms, and no prior sustained ventricular tachyarrhythmias to 1058 patients <80 years old implanted with CRT-D during the same timeframe. Comorbidities and medical therapy differed significantly between the groups. During 52 ± 36 months, 123 (48%) patients ≥80 and 474 (45%) patients <80 died; mortality was significantly higher among patients ≥80 [corrected hazard ratio (HR) 1.39, 95% confidence interval (CI) 1.12-1.72; P = 0.003]. Among 258 patients ≥80 with device follow-up, only 20 (8%) received an appropriate shock compared with 172 (17%) shocks in 1053 patients <80 years old. Time to first appropriate shock was significantly shorter in patients <80 (corrected HR 0.51, 95% CI 0.30-0.87, P = 0.013). Older patients experienced 14 inappropriate shocks, and while life-threatening device complications were rare, complications related to the high-power components of the CRT-D system were not infrequent (n = 11). Conclusion Mortality among CRT-D recipients ≥80 years old is higher than in younger patients but is not excessive. The risk of appropriate device shocks in older patients is relatively low and significantly less than in younger patients. These observations suggest that CRT-pacemakers should be given due consideration in elderly HF patients. Published on behalf of the European Society of Cardiology. All rights reserved.
AB - Aims Very elderly patients have not been well-represented in the randomized trials that established the benefits of cardiac resynchronization therapy (CRT) in heart failure (HF) patients. We therefore compared clinical outcomes in CRT-defibrillator (CRT-D) recipients ≥80 and <80 years old. Methods and results We compared mortality and time to first appropriate shock in 258 consecutive CRT-D patients ≥80 years old with New York Heart Association II-IV HF, left ventricular ejection fraction ≤35%, QRS duration ≥120 ms, and no prior sustained ventricular tachyarrhythmias to 1058 patients <80 years old implanted with CRT-D during the same timeframe. Comorbidities and medical therapy differed significantly between the groups. During 52 ± 36 months, 123 (48%) patients ≥80 and 474 (45%) patients <80 died; mortality was significantly higher among patients ≥80 [corrected hazard ratio (HR) 1.39, 95% confidence interval (CI) 1.12-1.72; P = 0.003]. Among 258 patients ≥80 with device follow-up, only 20 (8%) received an appropriate shock compared with 172 (17%) shocks in 1053 patients <80 years old. Time to first appropriate shock was significantly shorter in patients <80 (corrected HR 0.51, 95% CI 0.30-0.87, P = 0.013). Older patients experienced 14 inappropriate shocks, and while life-threatening device complications were rare, complications related to the high-power components of the CRT-D system were not infrequent (n = 11). Conclusion Mortality among CRT-D recipients ≥80 years old is higher than in younger patients but is not excessive. The risk of appropriate device shocks in older patients is relatively low and significantly less than in younger patients. These observations suggest that CRT-pacemakers should be given due consideration in elderly HF patients. Published on behalf of the European Society of Cardiology. All rights reserved.
UR - http://www.scopus.com/inward/record.url?scp=84965105283&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=84965105283&partnerID=8YFLogxK
U2 - 10.1093/europace/euv222
DO - 10.1093/europace/euv222
M3 - Article
C2 - 26487669
AN - SCOPUS:84965105283
SN - 1099-5129
VL - 18
SP - 420
EP - 427
JO - Europace
JF - Europace
IS - 3
ER -