TY - JOUR
T1 - Clinical Value of Tc99m-MIBI SPECT/CT Versus 4D-CT or US in Management of Patients With Hyperparathyroidism
AU - Kedarisetty, Suraj
AU - Fundakowski, Christopher
AU - Ramakrishnan, Karthika
AU - Dadparvar, Simin
N1 - Publisher Copyright:
© The Author(s) 2019.
PY - 2019/3/1
Y1 - 2019/3/1
N2 - Localization of parathyroid adenomas for treatment of primary hyperparathyroidism can be challenging. This retrospective study compared single-photon emission computed tomography/computed tomography (SPECT/CT), 4D-CT, and US studies in detection of adenomas prior to surgery. A retrospective chart review was performed on all consecutive patients with parathyroid adenoma presenting to an urban tertiary care medical center. A total of 58 patients (45 female, 13 male) underwent surgery for parathyroid adenoma. Patients aged 28 to 80 years (mean: 58.8) with parathyroid hormone levels ranging from 42 to 424 pg/mL (mean: 168). All patients underwent preoperative SPECT/CT with 20 mCi technetium-99m MIBI (99mTc-MIBI). Fifty-three patients had additional US imaging and 14 patients had 4D-CT scans. Additionally, 34 patients had injection of 20 mCi 99mTc-MIBI on the day of surgery. Pathological correlation was performed. Comparing SPECT/CT versus 4D-CT resulted in sensitivity (77% vs 80%), specificity (71% vs 75%), and accuracy (77% vs 79%). Ultrasound was less sensitive with similar specificity (44%, 86%, respectively). Combination of SPECT/CT and 4D-CT increased sensitivity to 88%, specificity to 100%, and accuracy to 89%. Combining SPECT/CT with US resulted in sensitivity of 85%, specificity of 83%, and accuracy of 85%. Intraoperative localization substantially improved in patients who received preoperative injections. The SPECT/CT remains the best imaging modality for preoperative localization of parathyroid adenomas with high sensitivity. Combining SPECT/CT with US resulted in increased sensitivity and accuracy. For suspicion of ectopic cases or suspicion of unidentifiable adenoma with negative scintigraphy, addition of 4D-CT is recommended. Intraoperative localization and adjunctive imaging may improve surgical management of patients with hyperparathyroidism.
AB - Localization of parathyroid adenomas for treatment of primary hyperparathyroidism can be challenging. This retrospective study compared single-photon emission computed tomography/computed tomography (SPECT/CT), 4D-CT, and US studies in detection of adenomas prior to surgery. A retrospective chart review was performed on all consecutive patients with parathyroid adenoma presenting to an urban tertiary care medical center. A total of 58 patients (45 female, 13 male) underwent surgery for parathyroid adenoma. Patients aged 28 to 80 years (mean: 58.8) with parathyroid hormone levels ranging from 42 to 424 pg/mL (mean: 168). All patients underwent preoperative SPECT/CT with 20 mCi technetium-99m MIBI (99mTc-MIBI). Fifty-three patients had additional US imaging and 14 patients had 4D-CT scans. Additionally, 34 patients had injection of 20 mCi 99mTc-MIBI on the day of surgery. Pathological correlation was performed. Comparing SPECT/CT versus 4D-CT resulted in sensitivity (77% vs 80%), specificity (71% vs 75%), and accuracy (77% vs 79%). Ultrasound was less sensitive with similar specificity (44%, 86%, respectively). Combination of SPECT/CT and 4D-CT increased sensitivity to 88%, specificity to 100%, and accuracy to 89%. Combining SPECT/CT with US resulted in sensitivity of 85%, specificity of 83%, and accuracy of 85%. Intraoperative localization substantially improved in patients who received preoperative injections. The SPECT/CT remains the best imaging modality for preoperative localization of parathyroid adenomas with high sensitivity. Combining SPECT/CT with US resulted in increased sensitivity and accuracy. For suspicion of ectopic cases or suspicion of unidentifiable adenoma with negative scintigraphy, addition of 4D-CT is recommended. Intraoperative localization and adjunctive imaging may improve surgical management of patients with hyperparathyroidism.
UR - https://www.scopus.com/pages/publications/85061969789
UR - https://www.scopus.com/inward/citedby.url?scp=85061969789&partnerID=8YFLogxK
U2 - 10.1177/0145561319828668
DO - 10.1177/0145561319828668
M3 - Article
C2 - 30938239
AN - SCOPUS:85061969789
SN - 0145-5613
VL - 98
SP - 149
EP - 157
JO - Ear, Nose and Throat Journal
JF - Ear, Nose and Throat Journal
IS - 3
ER -