TY - JOUR
T1 - Cold neutron prompt gamma activation analysis, a non-destructive technique for hydrogen level assessment in zirconium alloys
AU - Couet, Adrien
AU - Motta, Arthur T.
AU - Comstock, Robert J.
AU - Paul, Rick L.
N1 - Copyright:
Copyright 2012 Elsevier B.V., All rights reserved.
PY - 2012/6
Y1 - 2012/6
N2 - We propose a novel use of a non-destructive technique to quantitatively assess hydrogen concentration in zirconium alloys. The technique, called Cold Neutron Prompt Gamma Activation Analysis (CNPGAA), is based on measuring prompt gamma rays following the absorption of cold neutrons, and comparing the rate of detection of characteristic hydrogen gamma rays to that of gamma rays from matrix atoms. Because the emission is prompt, this method has to be performed in close proximity to a neutron source such as the one at the National Institute of Technology (NIST) Center for Neutron Research. Determination shown here to be simple and accurate, matching the results given by usual destructive techniques such as Vacuum Hot Extraction (VHE), with a precision of ±2 mg kg -1 (or wt ppm). Very low levels of hydrogen (as low as 5 mg kg -1 (wt ppm)) can be detected. Also, it is demonstrated that CNPGAA can be applied sequentially on an individual corrosion coupon during autoclave testing, to measure a gradually increasing hydrogen concentration. Thus, this technique can replace destructive techniques performed on "sister" samples thereby reducing experimental uncertainties.
AB - We propose a novel use of a non-destructive technique to quantitatively assess hydrogen concentration in zirconium alloys. The technique, called Cold Neutron Prompt Gamma Activation Analysis (CNPGAA), is based on measuring prompt gamma rays following the absorption of cold neutrons, and comparing the rate of detection of characteristic hydrogen gamma rays to that of gamma rays from matrix atoms. Because the emission is prompt, this method has to be performed in close proximity to a neutron source such as the one at the National Institute of Technology (NIST) Center for Neutron Research. Determination shown here to be simple and accurate, matching the results given by usual destructive techniques such as Vacuum Hot Extraction (VHE), with a precision of ±2 mg kg -1 (or wt ppm). Very low levels of hydrogen (as low as 5 mg kg -1 (wt ppm)) can be detected. Also, it is demonstrated that CNPGAA can be applied sequentially on an individual corrosion coupon during autoclave testing, to measure a gradually increasing hydrogen concentration. Thus, this technique can replace destructive techniques performed on "sister" samples thereby reducing experimental uncertainties.
UR - http://www.scopus.com/inward/record.url?scp=84860484098&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=84860484098&partnerID=8YFLogxK
U2 - 10.1016/j.jnucmat.2011.06.044
DO - 10.1016/j.jnucmat.2011.06.044
M3 - Article
AN - SCOPUS:84860484098
SN - 0022-3115
VL - 425
SP - 211
EP - 217
JO - Journal of Nuclear Materials
JF - Journal of Nuclear Materials
IS - 1-3
ER -