TY - JOUR
T1 - Comparison of artificial neural network (ANN) and partial least squares (PLS) regression models for predicting respiratory ventilation
T2 - An exploratory study
AU - Lin, Ming I.Brandon
AU - Groves, William A.
AU - Freivalds, Andris
AU - Lee, Eun Gyung
AU - Harper, Martin
PY - 2012/5
Y1 - 2012/5
N2 - The objective of this study was to assess the potential for using artificial neural networks (ANN) to predict inspired minute ventilation (V I) during exercise activities. Six physiological/kinematic measurements obtained from a portable ambulatory monitoring system, along with individual's anthropometric and demographic characteristics, were employed as input variables to develop and optimize the ANN configuration with respect to reference values simultaneously measured using a pneumotachograph (PT). The generalization ability of the resulting two-hidden-layer ANN model was compared with a linear predictive model developed through partial least squares (PLS) regression, as well as other VIpredictive models proposed in the literature. Using an independent dataset recorded from nine 80-min step tests, the results showed that the ANN-estimated VIwas highly correlated (R2= 0.88) with VI measured by the PT, with a mean difference of approximately 0.9%. In contrast, the PLS and other regression-based models resulted in larger average errors ranging from 7 to 34%. In addition, the ANN model yielded estimates of cumulative total volume that were on average within 1% of reference PT measurements. Compared with established statistical methods, the proposed ANN model demonstrates the potential to provide improved prediction of respiratory ventilation in workplace applications for which the use of traditional laboratorybased instruments is not feasible. Further research should be conducted to investigate the performance of ANNs for different types of physical activity in larger and more varied worker populations.
AB - The objective of this study was to assess the potential for using artificial neural networks (ANN) to predict inspired minute ventilation (V I) during exercise activities. Six physiological/kinematic measurements obtained from a portable ambulatory monitoring system, along with individual's anthropometric and demographic characteristics, were employed as input variables to develop and optimize the ANN configuration with respect to reference values simultaneously measured using a pneumotachograph (PT). The generalization ability of the resulting two-hidden-layer ANN model was compared with a linear predictive model developed through partial least squares (PLS) regression, as well as other VIpredictive models proposed in the literature. Using an independent dataset recorded from nine 80-min step tests, the results showed that the ANN-estimated VIwas highly correlated (R2= 0.88) with VI measured by the PT, with a mean difference of approximately 0.9%. In contrast, the PLS and other regression-based models resulted in larger average errors ranging from 7 to 34%. In addition, the ANN model yielded estimates of cumulative total volume that were on average within 1% of reference PT measurements. Compared with established statistical methods, the proposed ANN model demonstrates the potential to provide improved prediction of respiratory ventilation in workplace applications for which the use of traditional laboratorybased instruments is not feasible. Further research should be conducted to investigate the performance of ANNs for different types of physical activity in larger and more varied worker populations.
UR - http://www.scopus.com/inward/record.url?scp=84861527031&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=84861527031&partnerID=8YFLogxK
U2 - 10.1007/s00421-011-2118-6
DO - 10.1007/s00421-011-2118-6
M3 - Article
C2 - 21861111
AN - SCOPUS:84861527031
SN - 1439-6319
VL - 112
SP - 1603
EP - 1611
JO - European Journal of Applied Physiology
JF - European Journal of Applied Physiology
IS - 5
ER -