T1 - Comparison of perfusion quality in hollow-fiber membrane oxygenators for neonatal extracorporeal life support
AU - Talor, Jonathan
AU - Yee, Stella
AU - Rider, Alan
AU - Kunselman, Allen R.
AU - Guan, Yulong
AU - Ündar, Akif
PY - 2010/4
Y1 - 2010/4
N2 - Perfusion quality is an important issue in extracorporeal life support (ECLS); without adequate perfusion of the brain and other vital organs, multiorgan dysfunction and other deficits can result. The authors tested three different pediatric oxygenators (Medos Hilite 800 LT, Medtronic Minimax Plus, and Capiox Baby RX) to determine which gives the highest quality of perfusion at flow rates of 400, 600, and 800 mL/min using human blood (36°C, 40% hematocrit) under both nonpulsatile and pulsatile flow conditions. Clinically identical equipment and a pseudo-patient were used to mimic operating conditions during neonatal ECLS. Traditionally, the postoxygenator surplus hemodynamic energy value (SHEpost, extra energy obtained through pulsatile flow) is the one relied upon to give a qualitative determination of the amount of perfusion in the patient; the authors also examined SHE retention through the membrane, as well as the contribution of SHEpost to the postoxygenator total hemodynamic energy (THEpost). At each experimental condition, pulsatile flow outperformed nonpulsatile flow for all factors contributing to perfusion quality: the SHEpost values for pulsatile flow were 4.6-7.6 times greater than for nonpulsatile flow, while the THEpost remained nearly constant for pulsatile versus nonpulsatile flow. For both pulsatile and nonpulsatile flow, the Capiox Baby RX oxygenator was found to deliver the highest quality of perfusion, while the Minimax Plus oxygenator delivered the least perfusion. It is the authors' recommendation that the Baby RX oxygenator running under pulsatile flow conditions be used for pediatric ECLS, but further studies need to be done in order to establish its effectiveness beyond the FDA-approved time span.
AB - Perfusion quality is an important issue in extracorporeal life support (ECLS); without adequate perfusion of the brain and other vital organs, multiorgan dysfunction and other deficits can result. The authors tested three different pediatric oxygenators (Medos Hilite 800 LT, Medtronic Minimax Plus, and Capiox Baby RX) to determine which gives the highest quality of perfusion at flow rates of 400, 600, and 800 mL/min using human blood (36°C, 40% hematocrit) under both nonpulsatile and pulsatile flow conditions. Clinically identical equipment and a pseudo-patient were used to mimic operating conditions during neonatal ECLS. Traditionally, the postoxygenator surplus hemodynamic energy value (SHEpost, extra energy obtained through pulsatile flow) is the one relied upon to give a qualitative determination of the amount of perfusion in the patient; the authors also examined SHE retention through the membrane, as well as the contribution of SHEpost to the postoxygenator total hemodynamic energy (THEpost). At each experimental condition, pulsatile flow outperformed nonpulsatile flow for all factors contributing to perfusion quality: the SHEpost values for pulsatile flow were 4.6-7.6 times greater than for nonpulsatile flow, while the THEpost remained nearly constant for pulsatile versus nonpulsatile flow. For both pulsatile and nonpulsatile flow, the Capiox Baby RX oxygenator was found to deliver the highest quality of perfusion, while the Minimax Plus oxygenator delivered the least perfusion. It is the authors' recommendation that the Baby RX oxygenator running under pulsatile flow conditions be used for pediatric ECLS, but further studies need to be done in order to establish its effectiveness beyond the FDA-approved time span.
UR - http://www.scopus.com/inward/record.url?scp=77950882778&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=77950882778&partnerID=8YFLogxK
U2 - 10.1111/j.1525-1594.2009.00971.x
DO - 10.1111/j.1525-1594.2009.00971.x
M3 - Article
C2 - 20420601
AN - SCOPUS:77950882778
SN - 0160-564X
VL - 34
SP - E110-E116
JO - Artificial organs
JF - Artificial organs
IS - 4
ER -