N2 - Purpose: To compare the technical success of the Recovery and G2 filters as retrievable inferior vena cava (IVC) filters. Materials and Methods: Recovery (n = 128) and G2 (n = 113) filters were placed in the IVCs of 241 patients with the intent of retrieval. The referring physician and/or patient were contacted at 6-month intervals to ensure filter retrieval when indicated. The Recovery and G2 filter groups were compared regarding technical success of filter placement, technical success of attempted retrieval, filter tilt, filter migration, filter fracture, and filter efficacy. Results: Filter placement was technically successful in 95% of Recovery filters (n = 122) and 100% of G2 filters (n = 113). Recovery filter retrieval was attempted in 55% of patients (n = 71) at a mean of 228 days (range, 0-838 d) after filter placement. G2 filter retrieval was attempted in 55% of patients (n = 62) at a mean of 230 days (range, 7-617 d) after filter placement. Technical success rates of filter retrieval were 94% (n = 67) and 97% (n = 60) in the Recovery and G2 filter groups, respectively. The G2 filter group had significantly fewer cases of (i) filter tilt at placement, (ii) filter tilt at attempted retrieval, and (iii) filter fracture than the Recovery filter group. In the G2 filter group, there was a significantly higher technical success rate of filter placement and there were more cases of caudal filter migration than in the Recovery filter group. Conclusions: Compared with the Recovery filter, the G2 filter is associated with significantly less filter fracture and tilt, greater technical success of filter placement, and more caudal filter migration.
AB - Purpose: To compare the technical success of the Recovery and G2 filters as retrievable inferior vena cava (IVC) filters. Materials and Methods: Recovery (n = 128) and G2 (n = 113) filters were placed in the IVCs of 241 patients with the intent of retrieval. The referring physician and/or patient were contacted at 6-month intervals to ensure filter retrieval when indicated. The Recovery and G2 filter groups were compared regarding technical success of filter placement, technical success of attempted retrieval, filter tilt, filter migration, filter fracture, and filter efficacy. Results: Filter placement was technically successful in 95% of Recovery filters (n = 122) and 100% of G2 filters (n = 113). Recovery filter retrieval was attempted in 55% of patients (n = 71) at a mean of 228 days (range, 0-838 d) after filter placement. G2 filter retrieval was attempted in 55% of patients (n = 62) at a mean of 230 days (range, 7-617 d) after filter placement. Technical success rates of filter retrieval were 94% (n = 67) and 97% (n = 60) in the Recovery and G2 filter groups, respectively. The G2 filter group had significantly fewer cases of (i) filter tilt at placement, (ii) filter tilt at attempted retrieval, and (iii) filter fracture than the Recovery filter group. In the G2 filter group, there was a significantly higher technical success rate of filter placement and there were more cases of caudal filter migration than in the Recovery filter group. Conclusions: Compared with the Recovery filter, the G2 filter is associated with significantly less filter fracture and tilt, greater technical success of filter placement, and more caudal filter migration.
UR - http://www.scopus.com/inward/record.url?scp=69249232027&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=69249232027&partnerID=8YFLogxK
U2 - 10.1016/j.jvir.2009.05.037
DO - 10.1016/j.jvir.2009.05.037
M3 - Article
C2 - 19640733
AN - SCOPUS:69249232027
SN - 1051-0443
VL - 20
SP - 1193
EP - 1199
JO - Journal of Vascular and Interventional Radiology
JF - Journal of Vascular and Interventional Radiology
IS - 9
ER -