N2 - Surface electromyography (sEMG) plays a significant role in the everyday practice of clinic hand function rehabilitation. The materials and design of current typical clinic sEMG electrodes are rigid Ag/AgCl or flexible polyimide (PI) film, which cannot provide a stable interface between electrodes and skin for adequate long-term high-quality data. Thus, conformal, soft, breathable, wireless epidermal sEMG sensor systems have broad potential relevance to clinic rehabilitation settings. Herein, we demonstrate a stretchable epidermal sEMG sensor array system with optimized materials and structure strategies for hand gesture recognition and hand function rehabilitation. The optimized serpentine structures with marvelous stretchability and improved fill ratio, provide lower impedance and high-quality sEMG signals. Moreover, the easy-to-use airhole method further ensures stable and long-term contact with the skin for recording. In addition, integrated with a customized flexible wireless data acquisition system, the capability for real-time 8-channel sEMG monitoring is developed, and taking together with the CNN-based algorithm, the system can automatically and reliably realize the 7 kinds of hand gestures with an accuracy of 81.02%. Moreover, the low-cost yet high-performance epidermal sEMG sensor system demonstrated its conceptual feasibility in quantitatively evaluation of stroke patient's hand and facilitating human-robot collaboration in hand rehabilitation by proof-of-the-concept clinical testing.
AB - Surface electromyography (sEMG) plays a significant role in the everyday practice of clinic hand function rehabilitation. The materials and design of current typical clinic sEMG electrodes are rigid Ag/AgCl or flexible polyimide (PI) film, which cannot provide a stable interface between electrodes and skin for adequate long-term high-quality data. Thus, conformal, soft, breathable, wireless epidermal sEMG sensor systems have broad potential relevance to clinic rehabilitation settings. Herein, we demonstrate a stretchable epidermal sEMG sensor array system with optimized materials and structure strategies for hand gesture recognition and hand function rehabilitation. The optimized serpentine structures with marvelous stretchability and improved fill ratio, provide lower impedance and high-quality sEMG signals. Moreover, the easy-to-use airhole method further ensures stable and long-term contact with the skin for recording. In addition, integrated with a customized flexible wireless data acquisition system, the capability for real-time 8-channel sEMG monitoring is developed, and taking together with the CNN-based algorithm, the system can automatically and reliably realize the 7 kinds of hand gestures with an accuracy of 81.02%. Moreover, the low-cost yet high-performance epidermal sEMG sensor system demonstrated its conceptual feasibility in quantitatively evaluation of stroke patient's hand and facilitating human-robot collaboration in hand rehabilitation by proof-of-the-concept clinical testing.
UR - http://www.scopus.com/inward/record.url?scp=85194423513&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85194423513&partnerID=8YFLogxK
U2 - 10.1016/j.matdes.2024.113029
DO - 10.1016/j.matdes.2024.113029
M3 - Article
AN - SCOPUS:85194423513
SN - 0264-1275
VL - 243
JO - Materials and Design
JF - Materials and Design
M1 - 113029
ER -