T1 - CT Volumetry of Convoluted Objects-A Simple Method Using Volume Averaging
AU - Al-Senan, Rani
AU - Newhouse, Jeffrey H.
PY - 2021/4/13
Y1 - 2021/4/13
N2 - Accurate measurement of object volumes using computed tomography is often important but can be challenging, especially for finely convoluted objects with severe marginal blurring from volume averaging. We aimed to test the accuracy of a simple method for volumetry by constructing, scanning and analyzing a phantom object with these characteristics which consisted of a cluster of small lucite beads embedded in petroleum jelly. Our method involves drawing simple regions of interest containing the entirety of the object and a portion of the surrounding material and using its density, along with the densities of pure lucite and petroleum jelly and the slice thickness to calculate the volume of the object in each slice. Comparison of our results with the object's true volume showed the technique to be highly accurate, irrespective of slice thickness, image noise, reconstruction planes, spatial resolution and variations in regions of interest. We conclude that the method can be easily used for accurate volumetry in clinical and research scans without the need for specialized volumetry computer programs.
AB - Accurate measurement of object volumes using computed tomography is often important but can be challenging, especially for finely convoluted objects with severe marginal blurring from volume averaging. We aimed to test the accuracy of a simple method for volumetry by constructing, scanning and analyzing a phantom object with these characteristics which consisted of a cluster of small lucite beads embedded in petroleum jelly. Our method involves drawing simple regions of interest containing the entirety of the object and a portion of the surrounding material and using its density, along with the densities of pure lucite and petroleum jelly and the slice thickness to calculate the volume of the object in each slice. Comparison of our results with the object's true volume showed the technique to be highly accurate, irrespective of slice thickness, image noise, reconstruction planes, spatial resolution and variations in regions of interest. We conclude that the method can be easily used for accurate volumetry in clinical and research scans without the need for specialized volumetry computer programs.
UR - http://www.scopus.com/inward/record.url?scp=85105186163&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85105186163&partnerID=8YFLogxK
U2 - 10.3390/tomography7020011
DO - 10.3390/tomography7020011
M3 - Article
C2 - 33924342
AN - SCOPUS:85105186163
SN - 2379-1381
VL - 7
SP - 120
EP - 129
JO - Tomography (Ann Arbor, Mich.)
JF - Tomography (Ann Arbor, Mich.)
IS - 2
ER -