N2 - Enhanced fins are widely used in residential air conditioning system finned-tube condenser designs. While this heat transfer augmentation technique increases the heat transfer coefficient in the heat exchanger, it also increases the air side frictional pressure drop. These two effects compete with each other, making it difficult to determine the relative goodness between plain fin versus enhanced fin designs with realistic constraints. In the past, this design tradeoff has been largely determined by experimental trial and error or heuristic figures of merit. No studies are available showing the effect of fin augmentation on overall system performance under consistent cost and frontal area constraints. The residential air conditioning system model calculates all component and system performance parameters. The condenser design requires the specification of approximately ten design parameters. A search method is used to vary these ten parameters and reach an optimum design based on a COP (efficiency) figure-of-merit with condenser cost and other appropriate constraints. It was found that when optimized, louvered fin designs always show better system performance than the optimum plain fin design for the cases studied. However a decrease in system efficiency can result if louvers are merely added to a plain fin optimum design.
AB - Enhanced fins are widely used in residential air conditioning system finned-tube condenser designs. While this heat transfer augmentation technique increases the heat transfer coefficient in the heat exchanger, it also increases the air side frictional pressure drop. These two effects compete with each other, making it difficult to determine the relative goodness between plain fin versus enhanced fin designs with realistic constraints. In the past, this design tradeoff has been largely determined by experimental trial and error or heuristic figures of merit. No studies are available showing the effect of fin augmentation on overall system performance under consistent cost and frontal area constraints. The residential air conditioning system model calculates all component and system performance parameters. The condenser design requires the specification of approximately ten design parameters. A search method is used to vary these ten parameters and reach an optimum design based on a COP (efficiency) figure-of-merit with condenser cost and other appropriate constraints. It was found that when optimized, louvered fin designs always show better system performance than the optimum plain fin design for the cases studied. However a decrease in system efficiency can result if louvers are merely added to a plain fin optimum design.
UR - http://www.scopus.com/inward/record.url?scp=1842779890&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=1842779890&partnerID=8YFLogxK
U2 - 10.1115/ht2003-47271
DO - 10.1115/ht2003-47271
M3 - Conference contribution
AN - SCOPUS:1842779890
SN - 0791836932
SN - 9780791836934
T3 - Proceedings of the ASME Summer Heat Transfer Conference
SP - 703
EP - 710
BT - Proceedings of the 003 ASME Summer Heat Transfer Conference, Volume 1
PB - American Society of Mechanical Engineers
T2 - 2003 ASME Summer Heat Transfer Conference (HT2003)
Y2 - 21 July 2003 through 23 July 2003
ER -