Abstract
Presented in this paper is a theoretical review of the relationships that should exist between electrical winding parameters and the mechanical vibration of a-c machine elements under normal and faulted operating conditions. Also included is data from an experimental study that relates stator vibration and bearing vibration to selected winding faults in a synchronous machine. Consideration of these results indicates a significant relationship between electrical deterioration and mechanical vibration and thus provides the motivation for additional study and a basis for future applications.
Original language | English (US) |
---|---|
Pages (from-to) | 1903-1907 |
Number of pages | 5 |
Journal | Conference Record - IAS Annual Meeting (IEEE Industry Applications Society) |
Volume | 3 |
State | Published - Dec 1 1999 |
Event | Proceedings of the 1999 IEEE Industry Applications Conference - 34th IAS Annual Meeting - Phoenix, AZ, USA Duration: Oct 3 1999 → Oct 7 1999 |