TY - JOUR
T1 - Determination of cocaine, norcocaine, benzoylecgonine and ecgonine methyl ester in rat plasma by high-performance liquid chromatography with ultraviolet detection
AU - Virag, Laszlo
AU - Mets, Berend
AU - Jamdar, Subhash
N1 - Funding Information:
This study was supported in part by National Institute on Drug Abuse Grant RO1 DA 07588 (Principal investigator: Hisayo O. Morishima, M.D., Ph.D.). The authors acknowledge the assistance of Prof. Thomas B. Cooper (Department of Psychiatry) in performing the GC-MS confirmation of p-fluorococaine. Funding was grate-
PY - 1996/6/7
Y1 - 1996/6/7
N2 - An isocratic high-performance liquid chromatographic method with ultraviolet detection at 235 nm is described for the determination of cocaine and its metabolites benzoylecgonine, norcocaine and ecgonine methyl ester in rat plasma, collected during toxicity studies. Following simultaneous solid-phase extraction of all analytes and the internal standard tropacocaine, cocaine, benzoylecgonine and norcocaine were separated on a C18 column. Ecgonine methyl ester and cocaine were separated on coupled cyanopropyl and silica columns, following derivatization of ecgonine methyl ester to p-fluorococaine. The extraction efficiencies of these compounds from plasma ranged from 78 to 87%, while the limits of detection ranged from 35 to 90 ng/ml. The assay was linear from 300 to 5000 ng/ml, and the within-day precision 2 to 8% over this concentration range.
AB - An isocratic high-performance liquid chromatographic method with ultraviolet detection at 235 nm is described for the determination of cocaine and its metabolites benzoylecgonine, norcocaine and ecgonine methyl ester in rat plasma, collected during toxicity studies. Following simultaneous solid-phase extraction of all analytes and the internal standard tropacocaine, cocaine, benzoylecgonine and norcocaine were separated on a C18 column. Ecgonine methyl ester and cocaine were separated on coupled cyanopropyl and silica columns, following derivatization of ecgonine methyl ester to p-fluorococaine. The extraction efficiencies of these compounds from plasma ranged from 78 to 87%, while the limits of detection ranged from 35 to 90 ng/ml. The assay was linear from 300 to 5000 ng/ml, and the within-day precision 2 to 8% over this concentration range.
UR - http://www.scopus.com/inward/record.url?scp=0029899302&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=0029899302&partnerID=8YFLogxK
U2 - 10.1016/0378-4347(95)00525-0
DO - 10.1016/0378-4347(95)00525-0
M3 - Article
C2 - 8811435
AN - SCOPUS:0029899302
SN - 1572-6495
VL - 681
SP - 263
EP - 269
JO - Journal of Chromatography B: Biomedical Applications
JF - Journal of Chromatography B: Biomedical Applications
IS - 2
ER -