T1 - Development of a prototype anti-pollution filter for volatile anesthetics
AU - Nigro Neto, Caetano
AU - Andrade, Aron Jose Pazin
AU - Leal, Edir
AU - Bezerra, Francisco Jose Lucena
AU - Lomivorotov, Vladimir
AU - Landoni, Giovanni
N1 - Publisher Copyright:
© The Author(s) 2019.
PY - 2020/7/1
Y1 - 2020/7/1
N2 - Introduction: The use of volatile agents during cardiopulmonary bypass allows a “single drug anesthesia” and is associated with reduced peak postoperative troponin levels. Connecting the exhaust systems to the oxygenator’s gas outlet port is mandatory and allows to prevent operating room (but not atmospheric) pollution by volatile agents. The aim of this study was to create a prototype filter for volatile agents and to test its adsorption efficacy during an ex-vivo simulated conventional cardiopulmonary bypass test. Methods: We carried out bench tests to conceive a prototype filter that could prevent room and environment pollution without damaging membrane oxygenators. We performed the tests at the Engineering Center for Circulatory Assistance Laboratory, Dante Pazzanese Institute of Cardiology, São Paulo, Brazil. Bench tests included simulation of integral adsorption tests, filter dimensions and design, flow versus pressure curve, sizing, and tightness. Results: Calgon AT 410 was the best kind of activated charcoal granules for adsorption of sevoflurane, isoflurane, and desflurane. Filter dimension tests showed that a chamber of 30-cm width over 10-cm diameter filled with 200 g of the Calgon AT410 granules was the minimum required to fully adsorb sevoflurane for 90 min. Adsorption tests showed that the prototype filter fully adsorbed isoflurane in 100 ± 2.3 min, sevoflurane in 95 ± 3.4 min, and desflurane in 95 ± 4.3 min. Conclusion: The new version of our prototype filter adsorbed most of the volatile anesthetics agents during an ex-vivo simulated conventional cardiopulmonary bypass test.
AB - Introduction: The use of volatile agents during cardiopulmonary bypass allows a “single drug anesthesia” and is associated with reduced peak postoperative troponin levels. Connecting the exhaust systems to the oxygenator’s gas outlet port is mandatory and allows to prevent operating room (but not atmospheric) pollution by volatile agents. The aim of this study was to create a prototype filter for volatile agents and to test its adsorption efficacy during an ex-vivo simulated conventional cardiopulmonary bypass test. Methods: We carried out bench tests to conceive a prototype filter that could prevent room and environment pollution without damaging membrane oxygenators. We performed the tests at the Engineering Center for Circulatory Assistance Laboratory, Dante Pazzanese Institute of Cardiology, São Paulo, Brazil. Bench tests included simulation of integral adsorption tests, filter dimensions and design, flow versus pressure curve, sizing, and tightness. Results: Calgon AT 410 was the best kind of activated charcoal granules for adsorption of sevoflurane, isoflurane, and desflurane. Filter dimension tests showed that a chamber of 30-cm width over 10-cm diameter filled with 200 g of the Calgon AT410 granules was the minimum required to fully adsorb sevoflurane for 90 min. Adsorption tests showed that the prototype filter fully adsorbed isoflurane in 100 ± 2.3 min, sevoflurane in 95 ± 3.4 min, and desflurane in 95 ± 4.3 min. Conclusion: The new version of our prototype filter adsorbed most of the volatile anesthetics agents during an ex-vivo simulated conventional cardiopulmonary bypass test.
UR - https://www.scopus.com/pages/publications/85077385236
UR - https://www.scopus.com/pages/publications/85077385236#tab=citedBy
U2 - 10.1177/0391398819895991
DO - 10.1177/0391398819895991
M3 - Article
C2 - 31894709
AN - SCOPUS:85077385236
SN - 0391-3988
VL - 43
SP - 476
EP - 481
JO - International Journal of Artificial Organs
JF - International Journal of Artificial Organs
IS - 7
ER -