TY - JOUR
T1 - Development of aortic insufficiency in patients supported with continuous flow left ventricular assist devices
AU - Soleimani, Behzad
AU - Haouzi, Annick
AU - Manoskey, Angela
AU - Stephenson, Edward R.
AU - El-Banayosy, Aly
AU - Pae, Walter E.
N1 - Copyright:
Copyright 2013 Elsevier B.V., All rights reserved.
PY - 2012/7
Y1 - 2012/7
N2 - Development of aortic insufficiency (AI) in patients supported with continuous flow left ventricular assist devices (LVAD) can adversely affect pump performance. In this study, we examined the incidence of new AI after LVAD implant at our institution. Pre- and postoperative echocardiograms of 66 patients who received HeartMate II or Heartware LVAD at our institution since June 2008 were reviewed for presence of new AI. Median LVAD support duration was 221 days. New AI developed in 6 patients (9.5%) after a median time of 374.5 days of support. There were no cases of severe or symptomatic AI. There was no significant difference between the AI incidence between HeartMate II and Heartware recipients. For patients who remained on LVAD support at 6 and 12 months, freedom from AI was 100% and 68.4%, respectively. Age, destination therapy status, and duration of support were predictors of new AI after LVAD implant. In conclusion, AI develops frequently during long-term support with continuous flow LVADs, particularly in those supported for longer than 6 months. As we move to the era of long-term LVAD support and destination therapy, further studies with longer follow-ups are required to determine the progression and clinical significance of AI in these patients.
AB - Development of aortic insufficiency (AI) in patients supported with continuous flow left ventricular assist devices (LVAD) can adversely affect pump performance. In this study, we examined the incidence of new AI after LVAD implant at our institution. Pre- and postoperative echocardiograms of 66 patients who received HeartMate II or Heartware LVAD at our institution since June 2008 were reviewed for presence of new AI. Median LVAD support duration was 221 days. New AI developed in 6 patients (9.5%) after a median time of 374.5 days of support. There were no cases of severe or symptomatic AI. There was no significant difference between the AI incidence between HeartMate II and Heartware recipients. For patients who remained on LVAD support at 6 and 12 months, freedom from AI was 100% and 68.4%, respectively. Age, destination therapy status, and duration of support were predictors of new AI after LVAD implant. In conclusion, AI develops frequently during long-term support with continuous flow LVADs, particularly in those supported for longer than 6 months. As we move to the era of long-term LVAD support and destination therapy, further studies with longer follow-ups are required to determine the progression and clinical significance of AI in these patients.
UR - http://www.scopus.com/inward/record.url?scp=84863503715&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=84863503715&partnerID=8YFLogxK
U2 - 10.1097/MAT.0b013e318251cfff
DO - 10.1097/MAT.0b013e318251cfff
M3 - Article
C2 - 22569164
AN - SCOPUS:84863503715
SN - 1058-2916
VL - 58
SP - 326
EP - 329
JO - ASAIO Journal
JF - ASAIO Journal
IS - 4
ER -