TY - JOUR
T1 - Dioxin-like TEQ of women from the Seveso, Italy area by ID-HRGC/HRMS and CALUX
AU - Warner, Marcella
AU - Eskenazi, Brenda
AU - Patterson, Donald G.
AU - Clark, George
AU - Turner, Wayman E.
AU - Bonsignore, Luigi
AU - Mocarelli, Paolo
AU - Gerthoux, Pier Mario
N1 - Funding Information:
We gratefully acknowledge Stefania Casalini, PhD for coordinating data collection at Hospital of Desio. We would especially like to thank the women who participated in this study . This study was supported by Grant Numbers R01 ES07171 and F06 TW02075-01 from the National Institutes of Health, R82471 from the US Environmental Protection Agency, EA-M1977 from the Endometriosis Association, 2P30-ESO01896-17 from the National Institute of Environmental Health Sciences, and #2896 from Regione Lombardia and Fondazione Lombardia Ambiente, Milan, Italy .
PY - 2005/7
Y1 - 2005/7
N2 - Polychlorinated dibenzo-p-dioxins (PCDDs), polychlorinated dibenzofurans (PCDFs), and polychlorinated biphenyls (PCBs) are widespread environmental contaminants that exist as complex mixtures and are frequently detected at part-per-trillion (ppt) levels in humans. Using isotope dilution high-resolution gas chromatography/high-resolution mass spectrometry (HRGC/HRMS), we measure the PCDDs, PCDFs, and PCBs in serum of a population of 78 women residing in an area near Seveso, Italy where a TCDD explosion occurred in 1976 and where furniture is manufactured. The average total dioxin-like toxic equivalents (TEQ) of these women was 25.3 ppt, lipid-adjusted, comparable to other parts of Europe. TCDD levels, however, were higher among the few women who resided in the exposed area in 1976. We examined the possibility of using the CALUX (chemical-activated luciferase gene expression) bioassay to estimate total TEQ in a small volume of plasma from this population. A total of 32 archived plasma specimens were selected for CALUX bioassay, based on the distribution of Total TEQ by HRGC/HRMS. The CALUX bioassay was performed blind to HRGC/HRMS results with 2 ml plasma per replicate analysis. Of 32 samples, 10 were below detection limits in the CALUX bioassay. For the 32 samples, the CALUX-TEQ averaged 25.4 ppt, lipid-adjusted (range: 0-127.6) and was not significantly different from the HRGC/HRMS Total TEQ average of 31.2 ppt, lipid-adjusted (range: 12.7-88.3) (t = 0.88, P = 0.38). however, the two measures were not significantly correlated (Rs = 0.04, P = 0.82). More validation of the CALUX bioassay with larger sample volume is needed before application as an exposure measure in large-scale epidemiologic studies of health effects of dioxin-like compounds.
AB - Polychlorinated dibenzo-p-dioxins (PCDDs), polychlorinated dibenzofurans (PCDFs), and polychlorinated biphenyls (PCBs) are widespread environmental contaminants that exist as complex mixtures and are frequently detected at part-per-trillion (ppt) levels in humans. Using isotope dilution high-resolution gas chromatography/high-resolution mass spectrometry (HRGC/HRMS), we measure the PCDDs, PCDFs, and PCBs in serum of a population of 78 women residing in an area near Seveso, Italy where a TCDD explosion occurred in 1976 and where furniture is manufactured. The average total dioxin-like toxic equivalents (TEQ) of these women was 25.3 ppt, lipid-adjusted, comparable to other parts of Europe. TCDD levels, however, were higher among the few women who resided in the exposed area in 1976. We examined the possibility of using the CALUX (chemical-activated luciferase gene expression) bioassay to estimate total TEQ in a small volume of plasma from this population. A total of 32 archived plasma specimens were selected for CALUX bioassay, based on the distribution of Total TEQ by HRGC/HRMS. The CALUX bioassay was performed blind to HRGC/HRMS results with 2 ml plasma per replicate analysis. Of 32 samples, 10 were below detection limits in the CALUX bioassay. For the 32 samples, the CALUX-TEQ averaged 25.4 ppt, lipid-adjusted (range: 0-127.6) and was not significantly different from the HRGC/HRMS Total TEQ average of 31.2 ppt, lipid-adjusted (range: 12.7-88.3) (t = 0.88, P = 0.38). however, the two measures were not significantly correlated (Rs = 0.04, P = 0.82). More validation of the CALUX bioassay with larger sample volume is needed before application as an exposure measure in large-scale epidemiologic studies of health effects of dioxin-like compounds.
UR - http://www.scopus.com/inward/record.url?scp=23744474327&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=23744474327&partnerID=8YFLogxK
U2 - 10.1038/sj.jea.7500407
DO - 10.1038/sj.jea.7500407
M3 - Article
C2 - 15383834
AN - SCOPUS:23744474327
SN - 1053-4245
VL - 15
SP - 310
EP - 318
JO - Journal of Exposure Analysis and Environmental Epidemiology
JF - Journal of Exposure Analysis and Environmental Epidemiology
IS - 4
ER -