Direct mounting of quartz crystal on a CMOS PLL chip

Hyunsoo Kim, Tom Jackson, Jaehyun Lim, Kyusun Choi, Dave Kenny

Research output: Contribution to conferencePaperpeer-review

5 Scopus citations

Abstract

This paper reports progress on directly mounting a quartz crystal on a CMOS oscillator and PLL chip. This approach minimizes the distance between the quartz crystal resonator and the oscillator circuitry and can allow reduced power with reduced stray coupling effects. This approach also allows simplified packaging and can reduce the volume and weight of precision oscillators.

Original languageEnglish (US)
Pages165-168
Number of pages4
StatePublished - 2005
Event2004 IEEE International Frequency Control Symposium and Exposition. A Conference of the IEEE Ultrasonics, Ferroelectrics, and Frequency Control Society (UFFC-S) - Montreal, Canada
Duration: Aug 23 2004Aug 27 2004

Other

Other2004 IEEE International Frequency Control Symposium and Exposition. A Conference of the IEEE Ultrasonics, Ferroelectrics, and Frequency Control Society (UFFC-S)
Country/TerritoryCanada
CityMontreal
Period8/23/048/27/04

All Science Journal Classification (ASJC) codes

  • General Engineering

Fingerprint

Dive into the research topics of 'Direct mounting of quartz crystal on a CMOS PLL chip'. Together they form a unique fingerprint.

Cite this