TY - JOUR
T1 - Effects of focused ultrasound and dry needling on tendon mechanical properties
AU - Khandare, Sujata
AU - Smallcomb, Molly
AU - Butt, Ali A.
AU - Elliott, Jacob
AU - Simon, Julianna C.
AU - Vidt, Meghan E.
N1 - Publisher Copyright:
© 2021 Elsevier Ltd
PY - 2022/2
Y1 - 2022/2
N2 - Tendon injuries are extremely common, resulting in mechanically weaker tendons that could lead to tendon rupture. Dry needling (DN) is widely used to manage pain and function after injury. However, DN is invasive and high inter-practitioner variability has led to mixed success rates. Focused ultrasound (fUS) is a non-invasive medical technology that directs ultrasound energy into a well-defined focal volume. fUS can induce thermal ablation or mechanical fractionation, with bioeffect type controlled through ultrasound parameters. Tendons must withstand high physiological loads, thus treatments maintaining tendon mechanical properties while promoting healing are needed. Our objective was to evaluate mechanical effects of DN and 3 fUS parameter sets, chosen to prioritize mechanical fractionation, on Achilles and supraspinatus tendons. Ex vivo rat Achilles and supraspinatus tendons (50 each) were divided into sham, DN, fUS-1, fUS-2, and fUS-3 (n = 10/group). Following treatment, tendons were mechanically tested. Elastic modulus of supraspinatus tendons treated with DN (126.64 ± 28.1 MPa) was lower than sham (153.02 ± 29.3 MPa; p = 0.0280). Stiffness and percent relaxation of tendons treated with DN (Achilles: 114.40 ± 31.6 N/mm; 49.10 ± 6.1%; supraspinatus: 109.53 ± 30.8 N/mm; 50.17 ± 7.6%) were lower (all p < 0.0334) than sham (Achilles: 141.34 ± 20.9 N/mm; 60.30 ± 7.7%; supraspinatus: 135.14 ± 30.2 N/mm; 60.85 ± 15.4%). Modulus of Achilles and supraspinatus tendons treated with fUS-1 (159.88 ± 25.7 MPa; 150.12 ± 22.0 MPa, respectively) were similar to sham (156.35 ± 23.0 MPa; 153.02 ± 29.3 MPa, respectively). These results suggest that fUS preserves mechanical properties better than DN, with fUS-1 performing better than fUS-2 and fUS-3. fUS should be studied further to fully understand its mechanical and healing effects to help evaluate fUS as an alternative, non-invasive treatment for tendon injuries.
AB - Tendon injuries are extremely common, resulting in mechanically weaker tendons that could lead to tendon rupture. Dry needling (DN) is widely used to manage pain and function after injury. However, DN is invasive and high inter-practitioner variability has led to mixed success rates. Focused ultrasound (fUS) is a non-invasive medical technology that directs ultrasound energy into a well-defined focal volume. fUS can induce thermal ablation or mechanical fractionation, with bioeffect type controlled through ultrasound parameters. Tendons must withstand high physiological loads, thus treatments maintaining tendon mechanical properties while promoting healing are needed. Our objective was to evaluate mechanical effects of DN and 3 fUS parameter sets, chosen to prioritize mechanical fractionation, on Achilles and supraspinatus tendons. Ex vivo rat Achilles and supraspinatus tendons (50 each) were divided into sham, DN, fUS-1, fUS-2, and fUS-3 (n = 10/group). Following treatment, tendons were mechanically tested. Elastic modulus of supraspinatus tendons treated with DN (126.64 ± 28.1 MPa) was lower than sham (153.02 ± 29.3 MPa; p = 0.0280). Stiffness and percent relaxation of tendons treated with DN (Achilles: 114.40 ± 31.6 N/mm; 49.10 ± 6.1%; supraspinatus: 109.53 ± 30.8 N/mm; 50.17 ± 7.6%) were lower (all p < 0.0334) than sham (Achilles: 141.34 ± 20.9 N/mm; 60.30 ± 7.7%; supraspinatus: 135.14 ± 30.2 N/mm; 60.85 ± 15.4%). Modulus of Achilles and supraspinatus tendons treated with fUS-1 (159.88 ± 25.7 MPa; 150.12 ± 22.0 MPa, respectively) were similar to sham (156.35 ± 23.0 MPa; 153.02 ± 29.3 MPa, respectively). These results suggest that fUS preserves mechanical properties better than DN, with fUS-1 performing better than fUS-2 and fUS-3. fUS should be studied further to fully understand its mechanical and healing effects to help evaluate fUS as an alternative, non-invasive treatment for tendon injuries.
UR - http://www.scopus.com/inward/record.url?scp=85123371712&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85123371712&partnerID=8YFLogxK
U2 - 10.1016/j.jbiomech.2021.110934
DO - 10.1016/j.jbiomech.2021.110934
M3 - Article
C2 - 34995989
AN - SCOPUS:85123371712
SN - 0021-9290
VL - 132
JO - Journal of Biomechanics
JF - Journal of Biomechanics
M1 - 110934
ER -