TY - JOUR
T1 - Elastic phantoms generated by microfluidics technology
T2 - Validation of an imaged-based approach for accurate measurement of the growth rate of lung nodules
AU - El-Baz, Ayman
AU - Sethu, Palaniappan
AU - Gimel'farb, Georgy
AU - Khalifa, Fahmi
AU - Elnakib, Ahmed
AU - Falk, Robert
AU - El-Ghar, Mohamed Abo
PY - 2011/2
Y1 - 2011/2
N2 - This paper focuses on validating our approach for monitoring the development of lung nodules detected in successive chest low-dose computed tomography (LDCT) scans of a patient. Our methodology for monitoring detected lung nodules includes 3D LDCT data registration, which is a non-rigid technique and involves two steps: (i) global target-to-prototype alignment of one scan to another using the experience gained from a prior appearance model, followed by (ii) local alignment to correct for intricate relative deformations. We propose a new approach for validating the accuracy of our algorithm for elastic lung phantoms constructed with state-of-the-art microfluidics technology and in vivo data. Fabricated from a flexible transparent polymer, i.e. polydimethylsiloxane (PDMS), the phantoms mimic the contractions and expansions of the lung and nodules as seen during normal breathing. The in vivo data in our study had been collected from a small control group of four subjects and a larger test group of 27 subjects with known ground truth (biopsy diagnosis. The growth rate and diagnostic results for both phantoms and in vivo data confirm the high accuracy of our algorithm.
AB - This paper focuses on validating our approach for monitoring the development of lung nodules detected in successive chest low-dose computed tomography (LDCT) scans of a patient. Our methodology for monitoring detected lung nodules includes 3D LDCT data registration, which is a non-rigid technique and involves two steps: (i) global target-to-prototype alignment of one scan to another using the experience gained from a prior appearance model, followed by (ii) local alignment to correct for intricate relative deformations. We propose a new approach for validating the accuracy of our algorithm for elastic lung phantoms constructed with state-of-the-art microfluidics technology and in vivo data. Fabricated from a flexible transparent polymer, i.e. polydimethylsiloxane (PDMS), the phantoms mimic the contractions and expansions of the lung and nodules as seen during normal breathing. The in vivo data in our study had been collected from a small control group of four subjects and a larger test group of 27 subjects with known ground truth (biopsy diagnosis. The growth rate and diagnostic results for both phantoms and in vivo data confirm the high accuracy of our algorithm.
UR - http://www.scopus.com/inward/record.url?scp=79551628217&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=79551628217&partnerID=8YFLogxK
U2 - 10.1002/biot.201000105
DO - 10.1002/biot.201000105
M3 - Article
C2 - 21298804
AN - SCOPUS:79551628217
SN - 1860-6768
VL - 6
SP - 195
EP - 203
JO - Biotechnology Journal
JF - Biotechnology Journal
IS - 2
ER -