TY - JOUR
T1 - Electrochemical impedance spectroscopy and finite element analysis modeling of a 4-electrode humidity sensor for natural gas transportation pipelines
AU - Hall, Derek M.
AU - Duffy, Timothy
AU - Ziomek-Moroz, Margaret
AU - Lvov, Serguei N.
N1 - Publisher Copyright:
© 2019 Author(s).
PY - 2019/1/1
Y1 - 2019/1/1
N2 - Reliable corrosion monitoring of natural gas transmission lines is a major tool providing a foundation for safe management of natural gas infrastructures. Through the development of membrane-based electrochemical sensors which are able to function in low-conductivity gas environments, corrosion monitoring practices can be further strengthened by real-time monitoring of key risk factors such as relative humidity and corrosion rates of corrodible structures. In this work, we demonstrate and validate how a 4-electrode conductivity sensor can provide a means to monitor relative humidity in gases via electrochemical impedance spectroscopy through finite element analysis (FEA). For a relative humidity range of 5%-55%, the impedance response varied from 1 kΩ to 66 kΩ, showing a high sensitivity for gas humidity. To confirm that the measured impedance values reliably interpreted relative humidity, it was found that precise estimation of the sensor's cell constant was needed. FEA was used to assess how the cell constant depended on the electrode geometry, membrane geometry, and electrode placement within the sensor. Through this approach, assumptions about the characteristic area and length were validated using electrolyte equipotential and current density vector mapping. This reduced possible cell constant uncertainties by 70%. With a cell constant of 14.84 cm -1 , obtained via FEA, membrane conductivity values were in good agreement with published data.
AB - Reliable corrosion monitoring of natural gas transmission lines is a major tool providing a foundation for safe management of natural gas infrastructures. Through the development of membrane-based electrochemical sensors which are able to function in low-conductivity gas environments, corrosion monitoring practices can be further strengthened by real-time monitoring of key risk factors such as relative humidity and corrosion rates of corrodible structures. In this work, we demonstrate and validate how a 4-electrode conductivity sensor can provide a means to monitor relative humidity in gases via electrochemical impedance spectroscopy through finite element analysis (FEA). For a relative humidity range of 5%-55%, the impedance response varied from 1 kΩ to 66 kΩ, showing a high sensitivity for gas humidity. To confirm that the measured impedance values reliably interpreted relative humidity, it was found that precise estimation of the sensor's cell constant was needed. FEA was used to assess how the cell constant depended on the electrode geometry, membrane geometry, and electrode placement within the sensor. Through this approach, assumptions about the characteristic area and length were validated using electrolyte equipotential and current density vector mapping. This reduced possible cell constant uncertainties by 70%. With a cell constant of 14.84 cm -1 , obtained via FEA, membrane conductivity values were in good agreement with published data.
UR - http://www.scopus.com/inward/record.url?scp=85060176161&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85060176161&partnerID=8YFLogxK
U2 - 10.1063/1.5063465
DO - 10.1063/1.5063465
M3 - Article
C2 - 30709197
AN - SCOPUS:85060176161
SN - 0034-6748
VL - 90
JO - Review of Scientific Instruments
JF - Review of Scientific Instruments
IS - 1
M1 - 015005
ER -