TY - JOUR
T1 - Electrochemical study of multi-electrode microbial fuel cells under fed-batch and continuous flow conditions
AU - Ren, Lijiao
AU - Ahn, Yongtae
AU - Hou, Huijie
AU - Zhang, Fang
AU - Logan, Bruce E.
N1 - Funding Information:
The authors thank David Jones for help with the analytical measurements. This research is supported by Award KUS-I1-003-13 from the King Abdullah University of Science and Technology (KAUST) .
PY - 2014/7/1
Y1 - 2014/7/1
N2 - Power production of four hydraulically connected microbial fuel cells (MFCs) was compared with the reactors operated using individual electrical circuits (individual), and when four anodes were wired together and connected to four cathodes all wired together (combined), in fed-batch or continuous flow conditions. Power production under these different conditions could not be made based on a single resistance, but instead required polarization tests to assess individual performance relative to the combined MFCs. Based on the power curves, power produced by the combined MFCs (2.12 ± 0.03 mW, 200 ω) was the same as the summed power (2.13 mW, 50 ω) produced by the four individual reactors in fed-batch mode. With continuous flow through the four MFCs, the maximum power (0.59 ± 0.01 mW) produced by the combined MFCs was slightly lower than the summed maximum power of the four individual reactors (0.68 ± 0.02 mW). There was a small parasitic current flow from adjacent anodes and cathodes, but overall performance was relatively unaffected. These findings demonstrate that optimal power production by reactors hydraulically and electrically connected can be predicted from performance by individual reactors.
AB - Power production of four hydraulically connected microbial fuel cells (MFCs) was compared with the reactors operated using individual electrical circuits (individual), and when four anodes were wired together and connected to four cathodes all wired together (combined), in fed-batch or continuous flow conditions. Power production under these different conditions could not be made based on a single resistance, but instead required polarization tests to assess individual performance relative to the combined MFCs. Based on the power curves, power produced by the combined MFCs (2.12 ± 0.03 mW, 200 ω) was the same as the summed power (2.13 mW, 50 ω) produced by the four individual reactors in fed-batch mode. With continuous flow through the four MFCs, the maximum power (0.59 ± 0.01 mW) produced by the combined MFCs was slightly lower than the summed maximum power of the four individual reactors (0.68 ± 0.02 mW). There was a small parasitic current flow from adjacent anodes and cathodes, but overall performance was relatively unaffected. These findings demonstrate that optimal power production by reactors hydraulically and electrically connected can be predicted from performance by individual reactors.
UR - http://www.scopus.com/inward/record.url?scp=84897974564&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=84897974564&partnerID=8YFLogxK
U2 - 10.1016/j.jpowsour.2013.11.085
DO - 10.1016/j.jpowsour.2013.11.085
M3 - Article
AN - SCOPUS:84897974564
SN - 0378-7753
VL - 257
SP - 454
EP - 460
JO - Journal of Power Sources
JF - Journal of Power Sources
ER -