TY - JOUR
T1 - Emergency dispatcher assistance decreases time to defibrillation in a public venue
T2 - A randomized controlled trial
AU - Riyapan, Sattha
AU - Lubin, Jeffrey
N1 - Publisher Copyright:
© 2015 Elsevier Inc. All rights reserved.
Copyright:
Copyright 2017 Elsevier B.V., All rights reserved.
PY - 2016/3/1
Y1 - 2016/3/1
N2 - Background We attempted to determine the effect of prearrival instructions that included the specific location of automated external defibrillators (AEDs) in a public venue on the time to defibrillation in a simulated cardiac arrest scenario using untrained bystanders. Methods The study was a randomized controlled trial at an urban shopping mall. Participants were asked to retrieve an AED and come back to defibrillate a mannequin. Only the experimental group received the location of the AED. We measured the percentage of shocks that were delivered in less than 3 minutes from the start of the scenario and also recorded several other time intervals. Results Thirty-nine participants completed the study, with 20 participants in the experimental group. The median time to defibrillation in the experimental group was 2.6 minutes (interquartile range, 2.4-2.8) which was significantly less than the control group's median time of 5.9 minutes (interquartile range, 4.38-7.65). Ninety percent (95% confidence interval, 68.3%-98.8%) of the participants in the experimental group defibrillated within 3 minutes, which was significantly different from the control group (10.5%; 95% confidence interval, 1.3%-33.1%). Conclusion In this study, a prearrival protocol providing participants with the location of the nearest AED in a public building resulted in a significant decrease in the time required to deliver a simulated shock. Further investigations in various types of public settings are needed to confirm the results.
AB - Background We attempted to determine the effect of prearrival instructions that included the specific location of automated external defibrillators (AEDs) in a public venue on the time to defibrillation in a simulated cardiac arrest scenario using untrained bystanders. Methods The study was a randomized controlled trial at an urban shopping mall. Participants were asked to retrieve an AED and come back to defibrillate a mannequin. Only the experimental group received the location of the AED. We measured the percentage of shocks that were delivered in less than 3 minutes from the start of the scenario and also recorded several other time intervals. Results Thirty-nine participants completed the study, with 20 participants in the experimental group. The median time to defibrillation in the experimental group was 2.6 minutes (interquartile range, 2.4-2.8) which was significantly less than the control group's median time of 5.9 minutes (interquartile range, 4.38-7.65). Ninety percent (95% confidence interval, 68.3%-98.8%) of the participants in the experimental group defibrillated within 3 minutes, which was significantly different from the control group (10.5%; 95% confidence interval, 1.3%-33.1%). Conclusion In this study, a prearrival protocol providing participants with the location of the nearest AED in a public building resulted in a significant decrease in the time required to deliver a simulated shock. Further investigations in various types of public settings are needed to confirm the results.
UR - http://www.scopus.com/inward/record.url?scp=84954288190&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=84954288190&partnerID=8YFLogxK
U2 - 10.1016/j.ajem.2015.12.015
DO - 10.1016/j.ajem.2015.12.015
M3 - Article
C2 - 26792238
AN - SCOPUS:84954288190
SN - 0735-6757
VL - 34
SP - 590
EP - 593
JO - American Journal of Emergency Medicine
JF - American Journal of Emergency Medicine
IS - 3
ER -