TY - JOUR
T1 - Endotoxaemia during left ventricular assist device insertion
T2 - Relationship between risk factors and outcome
AU - O'Malley, Cath M.N.
AU - Frumento, R. J.
AU - Mets, B.
AU - Naka, Y.
AU - Bennett-Guerrero, E.
PY - 2004/1
Y1 - 2004/1
N2 - Background. Endotoxaemia, caused by splanchnic ischaemia during surgery, is believed to trigger systemic inflammation and cause postoperative organ dysfunction. A relationship between the plasma concentration of endotoxin during surgery and known risk factors for postoperative morbidity and mortality (e.g. age, abnormal gastric tonometric variables) and adverse outcome after surgery has not been demonstrated. Methods. In a prospective study, the plasma concentration of endotoxin was measured in 12 patients undergoing implantation of a left ventricular assist device. Automated air gastric tonometry was performed in all patients. The relationship between plasma endotoxin concentration, risk factors, and postoperative outcome was explored. Results. Carbon dioxide gap increased from 0.7 (0.3) to 3.6 (1.6) kPa at the end of surgery. Endotoxin was detected in one of 12 patients at baseline and in nine of 12 patients at the end of surgery (P=0.003). A high plasma concentration of endotoxin at the end of surgery was associated with a higher carbon dioxide gap (r=0.59, P<0.05), and a higher postoperative multiple organ dysfunction score (r=0.7, P=0.01). Conclusions. The finding of an association between high intraoperative plasma concentrations of endotoxin, abnormal gastric tonometric variables and adverse outcome supports the view that endotoxaemia is caused by gut hypoperfusion during surgery and is associated with postoperative organ dysfunction.
AB - Background. Endotoxaemia, caused by splanchnic ischaemia during surgery, is believed to trigger systemic inflammation and cause postoperative organ dysfunction. A relationship between the plasma concentration of endotoxin during surgery and known risk factors for postoperative morbidity and mortality (e.g. age, abnormal gastric tonometric variables) and adverse outcome after surgery has not been demonstrated. Methods. In a prospective study, the plasma concentration of endotoxin was measured in 12 patients undergoing implantation of a left ventricular assist device. Automated air gastric tonometry was performed in all patients. The relationship between plasma endotoxin concentration, risk factors, and postoperative outcome was explored. Results. Carbon dioxide gap increased from 0.7 (0.3) to 3.6 (1.6) kPa at the end of surgery. Endotoxin was detected in one of 12 patients at baseline and in nine of 12 patients at the end of surgery (P=0.003). A high plasma concentration of endotoxin at the end of surgery was associated with a higher carbon dioxide gap (r=0.59, P<0.05), and a higher postoperative multiple organ dysfunction score (r=0.7, P=0.01). Conclusions. The finding of an association between high intraoperative plasma concentrations of endotoxin, abnormal gastric tonometric variables and adverse outcome supports the view that endotoxaemia is caused by gut hypoperfusion during surgery and is associated with postoperative organ dysfunction.
UR - http://www.scopus.com/inward/record.url?scp=0346336772&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=0346336772&partnerID=8YFLogxK
U2 - 10.1093/bja/aeh010
DO - 10.1093/bja/aeh010
M3 - Article
C2 - 14665564
AN - SCOPUS:0346336772
SN - 0007-0912
VL - 92
SP - 131
EP - 133
JO - British Journal of Anaesthesia
JF - British Journal of Anaesthesia
IS - 1
ER -