TY - JOUR
T1 - Evaluating the efficacy of non-thermal microbial load reduction treatments of heat labile food components for in vitro fermentation experiments
AU - Paff, Andrew
AU - Cockburn, Darrell W.
N1 - Publisher Copyright:
© 2023 Paff, Cockburn. This is an open access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
PY - 2023/3
Y1 - 2023/3
N2 - Increasingly, in vitro simulated colon fermentations are being used as a pre-clinical step to assess the impacts of foods and drugs on the gut microbiota in a cost-effective manner. One challenge in such systems is that they are potentially susceptible to the influences of contaminating microbes in test materials. Simulated gastric and intestinal digestion can relieve some of these concerns, however, live microbes may remain that can confound analysis. Autoclave treatment of test materials is the surest way to eliminate these microbes but presents problems when using heat labile components such as resistant starch. In this study, liquid chemical sterilant alternatives to moist heat sterilization were explored for treating pulse flours for use during in vitro simulated colon fermentation. Key attributes considered in chemical selection were accessibility, impact on treated food components, and effectiveness of the treatments for reducing microbial load. Three chemicals were selected for evaluation, bleach, alcohol, and hydrogen peroxide, at varying concentrations. Flours chosen for testing were from green lentil, field pea, chickpea, or sprouted green lentil. All treatments significantly reduced microbial loads, though there were still detectable levels of microbes after alcohol treatments. Furthermore, in vitro simulated colon fermentations of the treated pulses showed minimal difference from the untreated control both in terms of microbial composition and short chain fatty acid production. Scanning electron microscopy showed minimal impact of sterilization treatments on the gross structure of the pulse flours. Together these results suggest that bleach and hydrogen peroxide treatments can be effective non-thermal treatments to eliminate contaminating microbes in pulse flours without causing significant damage to starch and other fermentable substrates. This is thus also a promising treatment method for other starchy food substrates, though further testing is required.
AB - Increasingly, in vitro simulated colon fermentations are being used as a pre-clinical step to assess the impacts of foods and drugs on the gut microbiota in a cost-effective manner. One challenge in such systems is that they are potentially susceptible to the influences of contaminating microbes in test materials. Simulated gastric and intestinal digestion can relieve some of these concerns, however, live microbes may remain that can confound analysis. Autoclave treatment of test materials is the surest way to eliminate these microbes but presents problems when using heat labile components such as resistant starch. In this study, liquid chemical sterilant alternatives to moist heat sterilization were explored for treating pulse flours for use during in vitro simulated colon fermentation. Key attributes considered in chemical selection were accessibility, impact on treated food components, and effectiveness of the treatments for reducing microbial load. Three chemicals were selected for evaluation, bleach, alcohol, and hydrogen peroxide, at varying concentrations. Flours chosen for testing were from green lentil, field pea, chickpea, or sprouted green lentil. All treatments significantly reduced microbial loads, though there were still detectable levels of microbes after alcohol treatments. Furthermore, in vitro simulated colon fermentations of the treated pulses showed minimal difference from the untreated control both in terms of microbial composition and short chain fatty acid production. Scanning electron microscopy showed minimal impact of sterilization treatments on the gross structure of the pulse flours. Together these results suggest that bleach and hydrogen peroxide treatments can be effective non-thermal treatments to eliminate contaminating microbes in pulse flours without causing significant damage to starch and other fermentable substrates. This is thus also a promising treatment method for other starchy food substrates, though further testing is required.
UR - http://www.scopus.com/inward/record.url?scp=85150669119&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85150669119&partnerID=8YFLogxK
U2 - 10.1371/journal.pone.0283287
DO - 10.1371/journal.pone.0283287
M3 - Article
C2 - 36943858
AN - SCOPUS:85150669119
SN - 1932-6203
VL - 18
JO - PloS one
JF - PloS one
IS - 3 March
M1 - e0283287
ER -