TY - JOUR
T1 - Experimental and numerical study on formation of interface separation and interfacial dielectric strength of GIL insulator
AU - Guo, Zihao
AU - Wu, Zehua
AU - Wang, Haoran
AU - Tian, Huidong
AU - Liu, Lilan
AU - Peng, Zongren
AU - Li, He
AU - Wang, Qing
N1 - Publisher Copyright:
© 1994-2012 IEEE.
PY - 2019/12
Y1 - 2019/12
N2 - As the transmission capacity of gas insulated transmission line (GIL) increases, the synergistic improvement in dielectric and mechanical strengths of GIL insulators is urgently needed for the development of advanced power systems. Mechanical defects in power equipment are prone to induce discharges during high voltage operations, which need to be mitigated. In this paper, the strains on the GIL insulator surface are measured by fiber Bragg grating (FBG) strain sensors during hydrostatic tests. An abnormal change of strain is detected near the interface between center conductor and the spacer. The numerical results of stress distributions of GIL insulator during manufacturing and high-voltage operation are calculated by the finite element method. The results indicate that the mechanical stresses are concentrated at the interface, which lead to the development of conductor-spacer interface separation. In addition, based on the hydrostatic test and the FEM calculations, the dielectric interfacial strength, including the electric field distribution, and flashover are investigated by a combination of numerical and experimental studies. The results indicate that the air gaps generated by the separated interface distort the electric field at the tip of the gap, which is likely to cause discharges and reduce the gas-solid interfacial flashover strength of the insulator, placing concerns of insulation failure and even operating failures of GIL. This work sheds light on the importance of interfacial structure of power equipment and will guide the design and the manufacture of GIL insulator.
AB - As the transmission capacity of gas insulated transmission line (GIL) increases, the synergistic improvement in dielectric and mechanical strengths of GIL insulators is urgently needed for the development of advanced power systems. Mechanical defects in power equipment are prone to induce discharges during high voltage operations, which need to be mitigated. In this paper, the strains on the GIL insulator surface are measured by fiber Bragg grating (FBG) strain sensors during hydrostatic tests. An abnormal change of strain is detected near the interface between center conductor and the spacer. The numerical results of stress distributions of GIL insulator during manufacturing and high-voltage operation are calculated by the finite element method. The results indicate that the mechanical stresses are concentrated at the interface, which lead to the development of conductor-spacer interface separation. In addition, based on the hydrostatic test and the FEM calculations, the dielectric interfacial strength, including the electric field distribution, and flashover are investigated by a combination of numerical and experimental studies. The results indicate that the air gaps generated by the separated interface distort the electric field at the tip of the gap, which is likely to cause discharges and reduce the gas-solid interfacial flashover strength of the insulator, placing concerns of insulation failure and even operating failures of GIL. This work sheds light on the importance of interfacial structure of power equipment and will guide the design and the manufacture of GIL insulator.
UR - http://www.scopus.com/inward/record.url?scp=85077709161&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85077709161&partnerID=8YFLogxK
U2 - 10.1109/TDEI.2019.008060
DO - 10.1109/TDEI.2019.008060
M3 - Article
AN - SCOPUS:85077709161
SN - 1070-9878
VL - 26
SP - 1738
EP - 1746
JO - IEEE Transactions on Dielectrics and Electrical Insulation
JF - IEEE Transactions on Dielectrics and Electrical Insulation
IS - 6
M1 - 8924102
ER -