TY - JOUR
T1 - Exposure measurement error in PM2.5 health effects studies
T2 - A pooled analysis of eight personal exposure validation studies
AU - Kioumourtzoglou, Marianthi Anna
AU - Spiegelman, Donna
AU - Szpiro, Adam A.
AU - Sheppard, Lianne
AU - Kaufman, Joel D.
AU - Yanosky, Jeff D.
AU - Williams, Ronald
AU - Laden, Francine
AU - Hong, Biling
AU - Suh, Helen
N1 - Funding Information:
This article was developed under STAR Fellowship Assistance Agreement (FP-9172890-01) from the US EPA. The views expressed here are those of the authors and do not necessarily reflect the views and policies of the US EPA. This manuscript has been subjected to U.S. EPA review and approved for publication. Additionally, this work was funded by NIH (ES 09411) and NIEHS (T32 ES 007069 and R01 ES017017).
PY - 2014/1/13
Y1 - 2014/1/13
N2 - Abstract. Background: Exposure measurement error is a concern in long-term PM2.5 health studies using ambient concentrations as exposures. We assessed error magnitude by estimating calibration coefficients as the association between personal PM2.5 exposures from validation studies and typically available surrogate exposures. Methods. Daily personal and ambient PM2.5, and when available sulfate, measurements were compiled from nine cities, over 2 to 12 days. True exposure was defined as personal exposure to PM2.5 of ambient origin. Since PM2.5 of ambient origin could only be determined for five cities, personal exposure to total PM 2.5 was also considered. Surrogate exposures were estimated as ambient PM2.5 at the nearest monitor or predicted outside subjects' homes. We estimated calibration coefficients by regressing true on surrogate exposures in random effects models. Results: When monthly-averaged personal PM2.5 of ambient origin was used as the true exposure, calibration coefficients equaled 0.31 (95% CI:0.14, 0.47) for nearest monitor and 0.54 (95% CI:0.42, 0.65) for outdoor home predictions. Between-city heterogeneity was not found for outdoor home PM2.5 for either true exposure. Heterogeneity was significant for nearest monitor PM2.5, for both true exposures, but not after adjusting for city-average motor vehicle number for total personal PM2.5. Conclusions: Calibration coefficients were <1, consistent with previously reported chronic health risks using nearest monitor exposures being under-estimated when ambient concentrations are the exposure of interest. Calibration coefficients were closer to 1 for outdoor home predictions, likely reflecting less spatial error. Further research is needed to determine how our findings can be incorporated in future health studies.
AB - Abstract. Background: Exposure measurement error is a concern in long-term PM2.5 health studies using ambient concentrations as exposures. We assessed error magnitude by estimating calibration coefficients as the association between personal PM2.5 exposures from validation studies and typically available surrogate exposures. Methods. Daily personal and ambient PM2.5, and when available sulfate, measurements were compiled from nine cities, over 2 to 12 days. True exposure was defined as personal exposure to PM2.5 of ambient origin. Since PM2.5 of ambient origin could only be determined for five cities, personal exposure to total PM 2.5 was also considered. Surrogate exposures were estimated as ambient PM2.5 at the nearest monitor or predicted outside subjects' homes. We estimated calibration coefficients by regressing true on surrogate exposures in random effects models. Results: When monthly-averaged personal PM2.5 of ambient origin was used as the true exposure, calibration coefficients equaled 0.31 (95% CI:0.14, 0.47) for nearest monitor and 0.54 (95% CI:0.42, 0.65) for outdoor home predictions. Between-city heterogeneity was not found for outdoor home PM2.5 for either true exposure. Heterogeneity was significant for nearest monitor PM2.5, for both true exposures, but not after adjusting for city-average motor vehicle number for total personal PM2.5. Conclusions: Calibration coefficients were <1, consistent with previously reported chronic health risks using nearest monitor exposures being under-estimated when ambient concentrations are the exposure of interest. Calibration coefficients were closer to 1 for outdoor home predictions, likely reflecting less spatial error. Further research is needed to determine how our findings can be incorporated in future health studies.
UR - http://www.scopus.com/inward/record.url?scp=84894279567&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=84894279567&partnerID=8YFLogxK
U2 - 10.1186/1476-069X-13-2
DO - 10.1186/1476-069X-13-2
M3 - Article
C2 - 24410940
AN - SCOPUS:84894279567
SN - 1476-069X
VL - 13
JO - Environmental Health: A Global Access Science Source
JF - Environmental Health: A Global Access Science Source
IS - 1
M1 - 2
ER -