TY - JOUR
T1 - Factors affecting radiation exposure during lumbar epidural steroid injection
T2 - A prospective study in 759 patients
AU - Kim, Suyoung
AU - Shin, Joon Ho
AU - Lee, Joon Woo
AU - Kang, Heung Sik
AU - Lee, Guen Young
AU - Ahn, Joong Mo
N1 - Publisher Copyright:
© 2016 The Korean Society of Radiology.
PY - 2016/5/1
Y1 - 2016/5/1
N2 - Objective: To estimate and compare radiation exposure and intervention time during lumbar epidural steroid injection (ESI) 1) under different practitioners and methods with continuous fluoroscopic monitoring, and 2) under one practitioner with different methods and monitoring. Materials and Methods: We consecutively recruited 804 patients who underwent lumbar ESI and 759 patients who underwent 922 interventions were included for analysis in this investigation. Three different practitioners (a senior faculty member, junior faculty member, trainee) performed lumbar ESI using different methods (caudal, interlaminar, transforaminal). The senior faculty member performed lumbar ESI under two different methods of fluoroscopic monitoring (continuous [CM] and intermittent monitoring [IM]). The dose area product (DAP) fluoroscopy time, and intervention time during lumbar ESI were compared for 1) ESI methods and practitioners under CM, and 2) ESI methods and monitoring. Results: With CM, interaction between the effects of the practitioner and the intervention on DAP was significant (p < 0.001), but not fluoroscopy time (p = 0.672) or intervention time (p = 0.852). The significant main effects included the practitioner and intervention on DAP, fluoroscopy time, and intervention time with CM (p < 0.001). DAPs and fluoroscopy time for caudal, interlaminar, and transforaminal ESI were higher with CM than with IM (p < 0.001). Intervention time did not differ between CM and IM. Conclusion: Radiation exposure is dependent on the practitioners and methods and within the established safety limits during lumbar ESIs under CM. With an experienced practitioner, IM leads to less radiation exposure than CM.
AB - Objective: To estimate and compare radiation exposure and intervention time during lumbar epidural steroid injection (ESI) 1) under different practitioners and methods with continuous fluoroscopic monitoring, and 2) under one practitioner with different methods and monitoring. Materials and Methods: We consecutively recruited 804 patients who underwent lumbar ESI and 759 patients who underwent 922 interventions were included for analysis in this investigation. Three different practitioners (a senior faculty member, junior faculty member, trainee) performed lumbar ESI using different methods (caudal, interlaminar, transforaminal). The senior faculty member performed lumbar ESI under two different methods of fluoroscopic monitoring (continuous [CM] and intermittent monitoring [IM]). The dose area product (DAP) fluoroscopy time, and intervention time during lumbar ESI were compared for 1) ESI methods and practitioners under CM, and 2) ESI methods and monitoring. Results: With CM, interaction between the effects of the practitioner and the intervention on DAP was significant (p < 0.001), but not fluoroscopy time (p = 0.672) or intervention time (p = 0.852). The significant main effects included the practitioner and intervention on DAP, fluoroscopy time, and intervention time with CM (p < 0.001). DAPs and fluoroscopy time for caudal, interlaminar, and transforaminal ESI were higher with CM than with IM (p < 0.001). Intervention time did not differ between CM and IM. Conclusion: Radiation exposure is dependent on the practitioners and methods and within the established safety limits during lumbar ESIs under CM. With an experienced practitioner, IM leads to less radiation exposure than CM.
UR - http://www.scopus.com/inward/record.url?scp=84964239546&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=84964239546&partnerID=8YFLogxK
U2 - 10.3348/kjr.2016.17.3.405
DO - 10.3348/kjr.2016.17.3.405
M3 - Article
C2 - 27134528
AN - SCOPUS:84964239546
SN - 1229-6929
VL - 17
SP - 405
EP - 412
JO - Korean Journal of Radiology
JF - Korean Journal of Radiology
IS - 3
ER -