T1 - Fast and precise voltage sag detection method for dynamic voltage restorer (DVR) application
AU - Khoshkbar Sadigh, A.
AU - Smedley, K. M.
N1 - Publisher Copyright:
© 2015 Published by Elsevier B.V.
PY - 2016/1/1
Y1 - 2016/1/1
N2 - Voltage sag detection method has a significant impact on the performance of dynamic voltage restorer (DVR). This paper proposes a fundamental voltage amplitude detection method which is applicable in both single/three-phase systems for DVR applications. Advantages of the proposed method include application in distorted power grid without any low-pass filter, precise and reliable detection, simple computation and implementation without using a phased locked loop and lookup table. The proposed method has been simulated and implemented experimentally and tested under various conditions considering all possible cases such as different amounts of voltage sag depth (VSD), different amounts of point-on-wave (POW) at which voltage sag occurs, harmonic distortion, line frequency variation, and phase jump (PJ). A detailed procedure to design the threshold band for comparator is presented. According to the achieved results and detailed analysis, maximum ripple of the calculated fundamental voltage amplitude is ±0.3% in normal condition of line frequency and ±1% in the case of ±1 Hz variation of 60 Hz line frequency. In addition, the error between the actual fundamental voltage amplitude and the calculated one is almost zero in normal condition of line frequency and maximum of ±0.25% in the case of line frequency variation with excessive-harmonic distortion. Furthermore, detection time (DT) of the proposed method is analyzed in detail for different amounts of VSD, POW and PJ. The best and worst detection time of the proposed method were measured 1 and 8.8 ms, respectively. Finally, the proposed method has been compared with other methods available in the literature.
AB - Voltage sag detection method has a significant impact on the performance of dynamic voltage restorer (DVR). This paper proposes a fundamental voltage amplitude detection method which is applicable in both single/three-phase systems for DVR applications. Advantages of the proposed method include application in distorted power grid without any low-pass filter, precise and reliable detection, simple computation and implementation without using a phased locked loop and lookup table. The proposed method has been simulated and implemented experimentally and tested under various conditions considering all possible cases such as different amounts of voltage sag depth (VSD), different amounts of point-on-wave (POW) at which voltage sag occurs, harmonic distortion, line frequency variation, and phase jump (PJ). A detailed procedure to design the threshold band for comparator is presented. According to the achieved results and detailed analysis, maximum ripple of the calculated fundamental voltage amplitude is ±0.3% in normal condition of line frequency and ±1% in the case of ±1 Hz variation of 60 Hz line frequency. In addition, the error between the actual fundamental voltage amplitude and the calculated one is almost zero in normal condition of line frequency and maximum of ±0.25% in the case of line frequency variation with excessive-harmonic distortion. Furthermore, detection time (DT) of the proposed method is analyzed in detail for different amounts of VSD, POW and PJ. The best and worst detection time of the proposed method were measured 1 and 8.8 ms, respectively. Finally, the proposed method has been compared with other methods available in the literature.
UR - http://www.scopus.com/inward/record.url?scp=84942532093&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=84942532093&partnerID=8YFLogxK
U2 - 10.1016/j.epsr.2015.08.002
DO - 10.1016/j.epsr.2015.08.002
M3 - Article
AN - SCOPUS:84942532093
SN - 0378-7796
VL - 130
SP - 192
EP - 207
JO - Electric Power Systems Research
JF - Electric Power Systems Research
ER -