TY - JOUR
T1 - Finger Force Estimation Using Motor Unit Discharges Across Forearm Postures
AU - Rubin, Noah
AU - Zheng, Yang
AU - Huang, He
AU - Hu, Xiaogang
N1 - Publisher Copyright:
© 1964-2012 IEEE.
PY - 2022/9/1
Y1 - 2022/9/1
N2 - Background: Myoelectric- based decoding has gained popularity in upper- limb neural-machine interfaces. Motor unit (MU) firings decomposed from surface electromyographic (EMG) signals can represent motor intent, but EMG properties at different arm configurations can change due to electrode shift and differing neuromuscular states. This study investigated whether isometric fingertip force estimation using MU firings is robust to forearm rotations from a neutral to either a fully pronated or supinated posture. Methods: We extracted MU information from high- density EMG of the extensor digitorum communis in two ways: (1) Decomposed EMG in all three postures (MU-AllPost); and (2) Decomposed EMG in neutral posture (MU-Neu), and extracted MUs (separation matrix) were applied to other postures. Populational MU firing frequency estimated forces scaled to subjects' maximum voluntary contraction (MVC) using a regression analysis. The results were compared with the conventional EMG-amplitude method. Results: We found largely similar root-mean-square errors (RMSE) for the two MU-methods, indicating that MU decomposition was robust to postural differences. MU-methods demonstrated lower RMSE in the ring (EMG = 6.23, MU-AllPost = 5.72, MU-Neu = 5.64% MVC) and pinky (EMG = 6.12, MU-AllPost = 4.95, MU-Neu = 5.36% MVC) fingers, with mixed results in the middle finger (EMG = 5.47, MU-AllPost = 5.52, MU-Neu = 6.19% MVC). Conclusion: Our results suggest that MU firings can be extracted reliably with little influence from forearm posture, highlighting its potential as an alternative decoding scheme for robust and continuous control of assistive devices.
AB - Background: Myoelectric- based decoding has gained popularity in upper- limb neural-machine interfaces. Motor unit (MU) firings decomposed from surface electromyographic (EMG) signals can represent motor intent, but EMG properties at different arm configurations can change due to electrode shift and differing neuromuscular states. This study investigated whether isometric fingertip force estimation using MU firings is robust to forearm rotations from a neutral to either a fully pronated or supinated posture. Methods: We extracted MU information from high- density EMG of the extensor digitorum communis in two ways: (1) Decomposed EMG in all three postures (MU-AllPost); and (2) Decomposed EMG in neutral posture (MU-Neu), and extracted MUs (separation matrix) were applied to other postures. Populational MU firing frequency estimated forces scaled to subjects' maximum voluntary contraction (MVC) using a regression analysis. The results were compared with the conventional EMG-amplitude method. Results: We found largely similar root-mean-square errors (RMSE) for the two MU-methods, indicating that MU decomposition was robust to postural differences. MU-methods demonstrated lower RMSE in the ring (EMG = 6.23, MU-AllPost = 5.72, MU-Neu = 5.64% MVC) and pinky (EMG = 6.12, MU-AllPost = 4.95, MU-Neu = 5.36% MVC) fingers, with mixed results in the middle finger (EMG = 5.47, MU-AllPost = 5.52, MU-Neu = 6.19% MVC). Conclusion: Our results suggest that MU firings can be extracted reliably with little influence from forearm posture, highlighting its potential as an alternative decoding scheme for robust and continuous control of assistive devices.
UR - http://www.scopus.com/inward/record.url?scp=85125331087&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85125331087&partnerID=8YFLogxK
U2 - 10.1109/TBME.2022.3153448
DO - 10.1109/TBME.2022.3153448
M3 - Article
C2 - 35213304
AN - SCOPUS:85125331087
SN - 0018-9294
VL - 69
SP - 2767
EP - 2775
JO - IEEE Transactions on Biomedical Engineering
JF - IEEE Transactions on Biomedical Engineering
IS - 9
ER -