Abstract
An important consideration for the design of seismic isolation systems composed of elastomeric bearings is the safety of individual bearings for maximum considered earthquake shaking. One assessment of bearing safety requires the bearing be stable at the maximum displacement. Although there exists no codified procedure for assessing stability in the laterally deformed configuration most engineers use the overlapping area method whereby the critical load capacity at zero lateral displacement is reduced by the ratio of the overlapping area between the top and bottom bearing end plates to the total bonded rubber area. This paper presents the results of a finite-element and experimental investigation aimed at improving the understanding of the stability of elastomeric bearing in the deformed configuration. The results of detailed nonlinear FE analysis and experimental testing of an elastomeric bearing with shape factor equal to 10 suggest the overlapping area method is overly conservative in predicting the critical load capacity in the deformed configuration.
Original language | English (US) |
---|---|
Pages | 1452-1461 |
Number of pages | 10 |
DOIs | |
State | Published - 2010 |
Event | Structures Congress 2010 - Orlando, FL, United States Duration: May 12 2010 → May 15 2010 |
Other
Other | Structures Congress 2010 |
---|---|
Country/Territory | United States |
City | Orlando, FL |
Period | 5/12/10 → 5/15/10 |
All Science Journal Classification (ASJC) codes
- Civil and Structural Engineering
- Building and Construction