TY - JOUR
T1 - Low-source-temperature diffusion absorption refrigeration. Part II
T2 - Experiments and model assessment
AU - Rattner, Alexander S.
AU - Garimella, Srinivas
N1 - Publisher Copyright:
© 2016 Elsevier Ltd and IIR
PY - 2016/5/1
Y1 - 2016/5/1
N2 - The diffusion absorption refrigeration cycle can enable passive fully thermally activated refrigeration for off-grid applications. In the accompanying paper, a new system configuration was proposed that employs alternate working fluids (NH3–NaSCN–He), a coupling-fluid heated bubble-pump generator, and an enhanced absorber. Detailed component and system level models were formulated for this design. In Part II of this work, the subject of this paper, these results are applied to implement a complete low-source-temperature (110–130 °C) passively cooled diffusion absorption refrigeration (DAR) system. Cooling was achieved at temperature ranges suitable for refrigeration (Tevap = 6 → 3 °C, COP ~ 0.06) and air-conditioning (12 → 8 °C, COP ~ 0.14). Device performance was also assessed at elevated ambient temperatures, reduced ambient air velocities, and varying system pressures. Results from this investigation agreed well with the predictions of the models developed in Part I.
AB - The diffusion absorption refrigeration cycle can enable passive fully thermally activated refrigeration for off-grid applications. In the accompanying paper, a new system configuration was proposed that employs alternate working fluids (NH3–NaSCN–He), a coupling-fluid heated bubble-pump generator, and an enhanced absorber. Detailed component and system level models were formulated for this design. In Part II of this work, the subject of this paper, these results are applied to implement a complete low-source-temperature (110–130 °C) passively cooled diffusion absorption refrigeration (DAR) system. Cooling was achieved at temperature ranges suitable for refrigeration (Tevap = 6 → 3 °C, COP ~ 0.06) and air-conditioning (12 → 8 °C, COP ~ 0.14). Device performance was also assessed at elevated ambient temperatures, reduced ambient air velocities, and varying system pressures. Results from this investigation agreed well with the predictions of the models developed in Part I.
UR - http://www.scopus.com/inward/record.url?scp=84992076966&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=84992076966&partnerID=8YFLogxK
U2 - 10.1016/j.ijrefrig.2015.11.016
DO - 10.1016/j.ijrefrig.2015.11.016
M3 - Article
AN - SCOPUS:84992076966
SN - 0140-7007
VL - 65
SP - 312
EP - 329
JO - International Journal of Refrigeration
JF - International Journal of Refrigeration
ER -