TY - JOUR
T1 - GeneMarker® HID
T2 - A Reliable Software Tool for the Analysis of Forensic STR Data
AU - Holland, Mitchell Mark
AU - Parson, Walther
PY - 2011/1/1
Y1 - 2011/1/1
N2 - GeneMarker® HID was assessed as a software tool for the analysis of forensic short tandem repeat (STR) data and as a resource for analysis of custom STR multiplexes. The software is easy to learn and use, and includes design features that have the potential to reduce user fatigue. To illustrate reliability and accuracy, STR data from both single-source and mixture profiles were analyzed and compared to profiles interpreted with another software package. A total of 1898 STR profiles representing 28,470 loci and more than 42,000 alleles were analyzed with 100% concordance. GeneMarker HID was also used to successfully analyze data generated from a custom STR multiplex, with simplified and rapid implementation. Finally, the impact of the user-friendly design features of the software was assessed through a time scale study. The results suggest that laboratories can reduce the time required for data analysis by at least 25% when using GeneMarker HID.
AB - GeneMarker® HID was assessed as a software tool for the analysis of forensic short tandem repeat (STR) data and as a resource for analysis of custom STR multiplexes. The software is easy to learn and use, and includes design features that have the potential to reduce user fatigue. To illustrate reliability and accuracy, STR data from both single-source and mixture profiles were analyzed and compared to profiles interpreted with another software package. A total of 1898 STR profiles representing 28,470 loci and more than 42,000 alleles were analyzed with 100% concordance. GeneMarker HID was also used to successfully analyze data generated from a custom STR multiplex, with simplified and rapid implementation. Finally, the impact of the user-friendly design features of the software was assessed through a time scale study. The results suggest that laboratories can reduce the time required for data analysis by at least 25% when using GeneMarker HID.
UR - http://www.scopus.com/inward/record.url?scp=78650734587&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=78650734587&partnerID=8YFLogxK
U2 - 10.1111/j.1556-4029.2010.01565.x
DO - 10.1111/j.1556-4029.2010.01565.x
M3 - Article
C2 - 20887353
AN - SCOPUS:78650734587
SN - 0022-1198
VL - 56
SP - 29
EP - 35
JO - Journal of Forensic Sciences
JF - Journal of Forensic Sciences
IS - 1
ER -