High resolution and low-cost test technique for unpopulated MCM substrate

Bruce C. Kim, Madhavan Swaminathan, Abhijit Chatterjee

Research output: Contribution to journalConference articlepeer-review

4 Scopus citations

Abstract

This paper describes a novel and low-cost technique for detecting process-related interconnect faults in Multichip Modules (MCMs). This method is an alternative to existing test methods such as TDNA, electron beam, electrical module test (EMT) and capacitance techniques which are either expensive in terms of test equipment, are cumbersome due to the requirement of multiple probes, or provide poor fault coverage. The new technique applies a stimulus through a resonator and a single ended probe at one end of the interconnect. By measuring the attenuation of the test stimulus due to pole movement relative to known attenuation measurements, interconnect faults such as latent opens, latent shorts, opens, and shorts can be detected.

Original languageEnglish (US)
Pages (from-to)226-233
Number of pages8
JournalProceedings - Electronic Components and Technology Conference
StatePublished - 1996
EventProceedings of the 1996 IEEE 46th Electronic Components & Technology Conference, ECTC - Orlando, FL, USA
Duration: May 28 1996May 31 1996

All Science Journal Classification (ASJC) codes

  • Electronic, Optical and Magnetic Materials
  • Electrical and Electronic Engineering

Fingerprint

Dive into the research topics of 'High resolution and low-cost test technique for unpopulated MCM substrate'. Together they form a unique fingerprint.

Cite this