TY - JOUR
T1 - Highly Sensitive Wearable Sensor Based on (001)-Orientated TiO2 for Real-Time Electrochemical Detection of Dopamine, Tyrosine, and Paracetamol
AU - Zhang, Tianyao
AU - Zhu, Jia
AU - Xie, Maowen
AU - Meng, Ke
AU - Yao, Guang
AU - Pan, Taisong
AU - Gao, Min
AU - Cheng, Huanyu
AU - Lin, Yuan
N1 - Publisher Copyright:
© 2024 The Authors. Small published by Wiley-VCH GmbH.
PY - 2024/5/29
Y1 - 2024/5/29
N2 - The concentration of dopamine (DA) and tyrosine (Tyr) reflects the condition of patients with Parkinson's disease, whereas moderate paracetamol (PA) can help relieve their pain. Therefore, real-time measurements of these bioanalytes have important clinical implications for patients with Parkinson's disease. However, previous sensors suffer from either limited sensitivity or complex fabrication and integration processes. This work introduces a simple and cost-effective method to prepare high-quality, flexible titanium dioxide (TiO2) thin films with highly reactive (001)-facets. The as-fabricated TiO2 film supported by a carbon cloth electrode (i.e., TiO2–CC) allows excellent electrochemical specificity and sensitivity to DA (1.390 µA µM−1 cm−2), Tyr (0.126 µA µM−1 cm−2), and PA (0.0841 µA µM−1 cm−2). More importantly, accurate DA concentration in varied pH conditions can be obtained by decoupling them within a single differential pulse voltammetry measurement without additional sensing units. The TiO2–CC electrochemical sensor can be integrated into a smart diaper to detect the trace amount of DA or an integrated skin-interfaced patch with microfluidic sampling and wireless transmission units for real-time detection of the sweat Try and PA concentration. The wearable sensor based on TiO2–CC prepared by facile manufacturing methods holds great potential in the daily health monitoring and care of patients with neurological disorders.
AB - The concentration of dopamine (DA) and tyrosine (Tyr) reflects the condition of patients with Parkinson's disease, whereas moderate paracetamol (PA) can help relieve their pain. Therefore, real-time measurements of these bioanalytes have important clinical implications for patients with Parkinson's disease. However, previous sensors suffer from either limited sensitivity or complex fabrication and integration processes. This work introduces a simple and cost-effective method to prepare high-quality, flexible titanium dioxide (TiO2) thin films with highly reactive (001)-facets. The as-fabricated TiO2 film supported by a carbon cloth electrode (i.e., TiO2–CC) allows excellent electrochemical specificity and sensitivity to DA (1.390 µA µM−1 cm−2), Tyr (0.126 µA µM−1 cm−2), and PA (0.0841 µA µM−1 cm−2). More importantly, accurate DA concentration in varied pH conditions can be obtained by decoupling them within a single differential pulse voltammetry measurement without additional sensing units. The TiO2–CC electrochemical sensor can be integrated into a smart diaper to detect the trace amount of DA or an integrated skin-interfaced patch with microfluidic sampling and wireless transmission units for real-time detection of the sweat Try and PA concentration. The wearable sensor based on TiO2–CC prepared by facile manufacturing methods holds great potential in the daily health monitoring and care of patients with neurological disorders.
UR - https://www.scopus.com/pages/publications/85184194586
UR - https://www.scopus.com/pages/publications/85184194586#tab=citedBy
U2 - 10.1002/smll.202312238
DO - 10.1002/smll.202312238
M3 - Article
C2 - 38319031
AN - SCOPUS:85184194586
SN - 1613-6810
VL - 20
JO - Small
JF - Small
IS - 22
M1 - 2312238
ER -