TY - JOUR
T1 - Human responses to bright light of different durations
AU - Chang, Anne Marie
AU - Santhi, Nayantara
AU - St Hilaire, Melissa
AU - Gronfier, Claude
AU - Bradstreet, Dayna S.
AU - Duffy, Jeanne F.
AU - Lockley, Steven W.
AU - Kronauer, Richard E.
AU - Czeisler, Charles A.
PY - 2012/7
Y1 - 2012/7
N2 - Light exposure in the early night induces phase delays of the circadian rhythm in melatonin in humans. Previous studies have investigated the effect of timing, intensity, wavelength, history and pattern of light stimuli on the human circadian timing system. We present results from a study of the duration-response relationship to phase-delaying bright light. Thirty-nine young healthy participants (16 female; 22.18 ± 3.62 years) completed a 9-day inpatient study. Following three baseline days, participants underwent an initial circadian phase assessment procedure in dim light (<3 lux), and were then randomized for exposure to a bright light pulse (~10,000 lux) of 0.2 h, 1.0 h, 2.5 h or 4.0 h duration during a 4.5 h controlled-posture episode centred in a 16 h wake episode. After another 8 h sleep episode, participants completed a second circadian phase assessment. Phase shifts were calculated from the difference in the clock time of the dim light melatonin onset (DLMO) between the initial and final phase assessments. Exposure to varying durations of bright light reset the circadian pacemaker in a dose-dependent, non-linear manner. Per minute of exposure, the 0.2 h duration was over 5 times more effective at phase delaying the circadian pacemaker (1.07 ± 0.36 h) as compared with the 4.0 h duration (2.65 ± 0.24 h). Acute melatonin suppression and subjective sleepiness also had a dose-dependent response to light exposure duration. These results provide strong evidence for a non-linear resetting response of the human circadian pacemaker to light duration.
AB - Light exposure in the early night induces phase delays of the circadian rhythm in melatonin in humans. Previous studies have investigated the effect of timing, intensity, wavelength, history and pattern of light stimuli on the human circadian timing system. We present results from a study of the duration-response relationship to phase-delaying bright light. Thirty-nine young healthy participants (16 female; 22.18 ± 3.62 years) completed a 9-day inpatient study. Following three baseline days, participants underwent an initial circadian phase assessment procedure in dim light (<3 lux), and were then randomized for exposure to a bright light pulse (~10,000 lux) of 0.2 h, 1.0 h, 2.5 h or 4.0 h duration during a 4.5 h controlled-posture episode centred in a 16 h wake episode. After another 8 h sleep episode, participants completed a second circadian phase assessment. Phase shifts were calculated from the difference in the clock time of the dim light melatonin onset (DLMO) between the initial and final phase assessments. Exposure to varying durations of bright light reset the circadian pacemaker in a dose-dependent, non-linear manner. Per minute of exposure, the 0.2 h duration was over 5 times more effective at phase delaying the circadian pacemaker (1.07 ± 0.36 h) as compared with the 4.0 h duration (2.65 ± 0.24 h). Acute melatonin suppression and subjective sleepiness also had a dose-dependent response to light exposure duration. These results provide strong evidence for a non-linear resetting response of the human circadian pacemaker to light duration.
UR - http://www.scopus.com/inward/record.url?scp=84863000137&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=84863000137&partnerID=8YFLogxK
U2 - 10.1113/jphysiol.2011.226555
DO - 10.1113/jphysiol.2011.226555
M3 - Article
C2 - 22526883
AN - SCOPUS:84863000137
SN - 0022-3751
VL - 590
SP - 3103
EP - 3112
JO - Journal of Physiology
JF - Journal of Physiology
IS - 13
ER -