Abstract
Super-twisting algorithm, a second-order sliding mode control method, is studied for hydropower plant frequency control. Two versions of this algorithm are introduced in this paper. Simulation results from both of these second-order methods and regular sliding mode control are compared on the basis of system responses and control efforts. It is shown that the second-order sliding mode controller is able to reduce chattering effects associated with the regular sliding mode control and preserve the robustness of the regular sliding mode control as well.
| Original language | English (US) |
|---|---|
| Article number | 074503 |
| Journal | Journal of Dynamic Systems, Measurement and Control, Transactions of the ASME |
| Volume | 139 |
| Issue number | 7 |
| DOIs | |
| State | Published - Jul 1 2017 |
All Science Journal Classification (ASJC) codes
- Control and Systems Engineering
- Information Systems
- Instrumentation
- Mechanical Engineering
- Computer Science Applications
Fingerprint
Dive into the research topics of 'Hydropower Plant Load Frequency Control Via Second-Order Sliding Mode'. Together they form a unique fingerprint.Cite this
- APA
- Author
- BIBTEX
- Harvard
- Standard
- RIS
- Vancouver