T1 - Impact of Humidification Systems on Ventilator-associated Pneumonia a Randomized Multicenter Trial
AU - Lacherade, Jean Claude
AU - Auburtin, Marc
AU - Cerf, Charles
AU - Van De Louw, Andry
AU - Soufir, Lilia
AU - Rebufat, Yves
AU - Rezaiguia, Saïda
AU - Ricard, Jean Damien
AU - Lellouche, François
AU - Brun-Buisson, Christian
AU - Brochard, Laurent
PY - 2005/11/15
Y1 - 2005/11/15
N2 - Rationale and objectives: The respective influence on the incidence of ventilator-associated pneumonia of currently available systems used for warming and humidifying the gases delivered to mechanically ventilated patients, that is, heated humidifiers and heat and moisture exchanger filters, remains controversial. Methods: We addressed this question in a multicenter randomized study comparing heated humidifiers (with heated circuits) and filters in an unselected population of 369 intensive care patients receiving mechanical ventilation for more than 48 h. Main Measurements and Results: The diagnosis of pneumonia was confirmed according to strict microbiologic criteria. There was no difference in pneumonia rate between the two groups (53 of 184 [28.8%] versus 47 of 185 [25.4%] for humidifiers versus filters; p = 0.48), or in the incidence density of pneumonia (27.4/1,000 ventilatory days versus 25.3/1,000 ventilatory days for humidifiers versus filters; p = 0.76). The mean duration of mechanical ventilation did not differ between the two groups (14.9 ± 15.1 versus 13.5 ± 16.3 days for humidifiers versus filters, p = 0.36). Endotracheal tube occlusion occurred, respectively, in five patients and one patient in the humidifier and filter groups (p = 0.12). Intensive care mortality was identical in the two groups (about 33%). Conclusion: These results suggest that both heated humidifiers and heat and moisture exchanger filters can be used with no significant impact on the incidence of ventilator-associated pneumonia and that other criteria may justify their choice.
AB - Rationale and objectives: The respective influence on the incidence of ventilator-associated pneumonia of currently available systems used for warming and humidifying the gases delivered to mechanically ventilated patients, that is, heated humidifiers and heat and moisture exchanger filters, remains controversial. Methods: We addressed this question in a multicenter randomized study comparing heated humidifiers (with heated circuits) and filters in an unselected population of 369 intensive care patients receiving mechanical ventilation for more than 48 h. Main Measurements and Results: The diagnosis of pneumonia was confirmed according to strict microbiologic criteria. There was no difference in pneumonia rate between the two groups (53 of 184 [28.8%] versus 47 of 185 [25.4%] for humidifiers versus filters; p = 0.48), or in the incidence density of pneumonia (27.4/1,000 ventilatory days versus 25.3/1,000 ventilatory days for humidifiers versus filters; p = 0.76). The mean duration of mechanical ventilation did not differ between the two groups (14.9 ± 15.1 versus 13.5 ± 16.3 days for humidifiers versus filters, p = 0.36). Endotracheal tube occlusion occurred, respectively, in five patients and one patient in the humidifier and filter groups (p = 0.12). Intensive care mortality was identical in the two groups (about 33%). Conclusion: These results suggest that both heated humidifiers and heat and moisture exchanger filters can be used with no significant impact on the incidence of ventilator-associated pneumonia and that other criteria may justify their choice.
UR - http://www.scopus.com/inward/record.url?scp=30444447238&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=30444447238&partnerID=8YFLogxK
U2 - 10.1164/rccm.200408-1028OC
DO - 10.1164/rccm.200408-1028OC
M3 - Article
C2 - 16126933
AN - SCOPUS:30444447238
SN - 1073-449X
VL - 172
SP - 1276
EP - 1282
JO - American journal of respiratory and critical care medicine
JF - American journal of respiratory and critical care medicine
IS - 10
ER -