T1 - Impact of inertia & effective short circuit ratio on control of frequency in weak grids interfacing LCC-HVDC & DFIG-based wind farms
AU - Yogarathinam, Amirthagunaraj
AU - Kaur, Jagdeep
AU - Chaudhuri, Nilanjan Ray
N1 - Publisher Copyright:
© 2016 IEEE.
PY - 2017/8
Y1 - 2017/8
N2 - Although virtually every overhead HVdc line is based on line commutated converter (LCC) technology, hardly any work has been reported on modeling and analysis of the impact of inertia and effective short circuit ratio on control of frequency in weak grids interfacing LCC-HVdc and onshore doubly fed induction generator (DFIG)-based wind farms. This paper develops a comprehensive modeling and stability analysis framework of a weak grid that interfaces an LCC-HVdc station and a DFIG-based wind farm. To that end, a nonlinear averaged phasormodel of the system is derived, which is then benchmarked against a detailed switched model. The averaged model is linearized to design a frequency controller for the LCC-HVdc rectifier station. Participation factor and eigenvalue sensitivity measures indicate that the ac system electromechanical mode and the "HVdc PLL" mode are highly sensitive to changes in effective dc inertia constant and effective short circuit ratio, respectively. Root-locus analysis in a progressively weak grid validates these results. A systematic design process of the frequency controller parameters reveals a negative interaction between the "generator speed-HVdc PLL-frequency controller" mode and the "DFIG-GSC controller" mode.
AB - Although virtually every overhead HVdc line is based on line commutated converter (LCC) technology, hardly any work has been reported on modeling and analysis of the impact of inertia and effective short circuit ratio on control of frequency in weak grids interfacing LCC-HVdc and onshore doubly fed induction generator (DFIG)-based wind farms. This paper develops a comprehensive modeling and stability analysis framework of a weak grid that interfaces an LCC-HVdc station and a DFIG-based wind farm. To that end, a nonlinear averaged phasormodel of the system is derived, which is then benchmarked against a detailed switched model. The averaged model is linearized to design a frequency controller for the LCC-HVdc rectifier station. Participation factor and eigenvalue sensitivity measures indicate that the ac system electromechanical mode and the "HVdc PLL" mode are highly sensitive to changes in effective dc inertia constant and effective short circuit ratio, respectively. Root-locus analysis in a progressively weak grid validates these results. A systematic design process of the frequency controller parameters reveals a negative interaction between the "generator speed-HVdc PLL-frequency controller" mode and the "DFIG-GSC controller" mode.
UR - http://www.scopus.com/inward/record.url?scp=85021775344&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85021775344&partnerID=8YFLogxK
U2 - 10.1109/TPWRD.2016.2607205
DO - 10.1109/TPWRD.2016.2607205
M3 - Article
AN - SCOPUS:85021775344
SN - 0885-8977
VL - 32
SP - 2040
EP - 2051
JO - IEEE Transactions on Power Delivery
JF - IEEE Transactions on Power Delivery
IS - 4
M1 - 7563401
ER -